Normal operation
52
11.6 Emergency
mode
In case a safety device LSA, LSI, SLA, or SLZ is faulty, emergency mode is possible. After a warning
time of 10 seconds, the gate can be moved in an emergency mode by using BA or BZ (dead man’s
function). During the warning time as well as during the emergency mode the waning light is flashing.
Emergency mode by radio remote control (BT or BTG) is not possible due to safety reasons.
After the power is switched on the gate position is not known, Emergency mode is possible during
starting mode after power is switched on but only the slow mode is available and the gate wings close
one after the other.
ATTENTION!
The use of signal generators, which are issuing a signal of more than 2
seconds duration (e.g. timers, induction loop detectors, key switches, radio
remote control receivers) is prohibited. Otherwise the installation works in
dangerous operation, when a safety device fails.
WARNING!
Risk of crushing!
Even when a safety device is faulty the gate can be moved using BA and BZ.
The buttons BA and BZ therefore have to be installed in such a way, that the gate can be
seen during movement.
WARNING!
Risk of crushing!
In case the multi-functional relay is used for an additional radio remote control channel
connected to BA or BZ, the emergency mode can be started by radio remote control.
In this case only fixed transmitters should be used in such a way, that the gate can be seen
during movement from the location of the transmitter.
WARNING!
Risk of crushing!
Are external devices, which give a constant signal, connected to BA or BZ, these devices
can start the emergency mode and move the gate when a safety device is faulty or
activated.