Technical data controller MO 36
56
14
Technical data controller MO 36
14.1 Constant
values
Parameter Value
Restart interlock after deactivating the motor
500ms
Reversing for a short distance on obstacle
500ms
Time lag before reversing
200ms
Max. running time limit during programming
500s
Running time reserve during normal mode
10s
Warning time prior to emergency mode
10s
Table 26
14.2
Changeable values and factory setting
Parameter Adjustment
range
Factory
setting
Running distance
max. 32.000 impulses
3.000 impulses
Force
1 to 99
30
Speed
1 to 8
8
Time lag during opening
0s up to 9s
2s
Time lag during closing
0s up to 9s
5s
Stay-open time for both
wings
1s up to 299s / OFF
OFF
Stay-open time for
pedestrian wing
1s up to 299s / OFF
OFF
Wind blast suppression
0s up to 9s
0s
Warning prior to opening
0s or 4s
0s
Warning prior to closing
0s or 4s
0s
Pressure relief of
electromagnetic bolt
0s or 1s or 2s or 90s
0s
Multi-functional relay
Funk-Tast or Funk-Toggle or
light pulse
Funk-Tast
Lockage function
ON / OFF
OFF
Photoelectric barrier
function
L1 or L2 or L3
L1
Number of wings
Gates with 1- or 2-wings
Gates with 1 wing
Photoelectric barrier
ON / OFF
OFF
Radio remote control
code BT
X-coding
- + - + - + - + -
Radio remote control
code BTG
X-coding deleted
Radio remote control
code MULTI
X-coding deleted
Table 27