Declaration of incorporation
9
4.1
Installation information for partly completed machinery
The partly completed machinery must not be put into service until the final machinery into
which it has to be incorporated has been declared inconformity with the provisions of the
machinery directive.
The safety functions of the controller comply with EN ISO 13849-1:2008
Kat.2PL d.
According to EC Directive 2006/42/EG the mains supply has to be equipped
with an all-pole circuit breaker.
WARNING!
Danger through voltage!
Danger of an electric shock.
Only certified electricians (VDE 0100) should connect the controller to the
mains supply.
According to DIN EN 12453, for an application with passenger traffic,
depending on the type of use and type of activation, suitable safety devices
have to be installed additionally, in order to provide the minimum level of
protection.
4.2
Declaration of conformity
After installation of the gate opener, the person responsible for the installation (in accordance with DIN
EN 13241-1) has to issue - according to the directive 2006/42/EEC- a declaration of conformity for the
gate system (gate plus swing gate opener).
4.3 Nameplate
The nameplate of the swing gate opener is fitted on the fixing bracket under the hood.