1000002042 (Rev. F - 08/17)
EMASMB*A & LMASMB*A
Page 6
SETTING THE CONTROL BOARD
VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the unit will
need to be shut down and restarted. The chiller (if present)
does not need to be shut down and restarted.
2) Shut down the unit by removing a battery.
3) Restart the unit by installing the batteries
4) Upon start up the bottle count display will show the software
designation of 'ELKAY BC'.
ACCESSING THE PROGRAMING BUTTON
1) To access the program button, remove the two (2) screws
holding the Bottom Cover in place. Button is located within
finger reach from the underside of the unit on the back right
hand side of the battery/filter tray.
2) When finished setting control board, reinstall the Bottom Cover
and secure with the same two (2) screws.
RESET THE FILTER MONITOR
1) Instructions apply to
filtered units only
.
2) Depress the program button momentarily. The display changes
when released. The display will change and scroll through four
messages:
“RST FLTR” – Reset Filter Status LED
“NO FLTR” – EMASMB or non-filtered mode
"500G FLT" – LMASMB or Filtered mode
"RST BCNT“ - Reset bottle count
If the program button is not pushed again the display will scroll
through the four messages above for and then default back to
bottle count and be back in run mode.
3) When the display changes to “RST FLTR”, depress the button
again. The display will change to show “FC RESET”. Depress
the button again and the display will show “00000000”
4) There are three (3) LED's that indicate the following:
Green
: LED (Good) indicates that the filter is operating
within 0% - 80% of its life.
Yellow
: LED indicates that the filter is operating within
80% - 100% of its life.
Red
: LED (Replace) indicates that the filter needs to be
replaced since it has reached end of filter life and flow
restrictions.
RESETTING BOTTLE COUNT
1) Depress the program button momentarily. The display will
change and scroll through four messages:
“RST FLTR” – Reset Filter Status LED
“NO FLTR” – EMASMB or non-filtered mode
"500G FLT" – LMASMB or Filtered mode
"1500G FLT" – NOT AVAILABLE - LMASMB
"3000G FLT" – NOT AVAILABLE - LMASMB
"6000G FLT" – NOT AVAILABLE - LMASMB
“RST BCNT“ – Reset bottle count
If the program button is not pushed again the display will scroll
through the four messages above for and then default back to
bottle count and be back in run mode. 2) When the display
changes to “RST BCNT”, push the button again and the display
will show “BC RESET” If the button is not pushed again the
display will return to run mode.
3) Push the program button once more to reset back to 0. The
display will and then return to run mode showing 00000000
bottles.
NOTE: Once the bottle count is reset to zero there is no way
to return to the previous bottle count.
4) Testing the bottle counter:
EMASMB units: Push button for approximately 9 seconds to see
bottle counter count 00000001.
NOTE: Bottle count is approximate and is dependent on water
pressure and flow through the filter. LMASMB units: Push
button for approximately 19 seconds to see bottle counter count
00000001. NOTE: Bottle count is approximate and is dependent
on water pressure and flow restrictions.
DESCRIPTION
1000001673
98546C
56192C
KIT-1.0 GPM REGULATOR KIT
KIT-AERATOR
REPLACEMENT FILTER
REPLACEMENT PARTS
PART NO.
REGULATOR
AERATOR
FILTER
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
B
C
A
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C
BATTERY CONFIGURATION
RESET SWITCH
FIG. 3