background image

(((ELKRON))) - CT10-M / CT11-M

2

Table of contents

1.0 Description of LEDs and buttons ............................................ 3

1.1 Description of the LEDs .................................................... 3

12

Description of the buttons ................................................ 3

2.0 Language selection............................................................. 4

2.1 Language selection ......................................................... 4

2.2 Viewing system status ..................................................... 4

3.0 User programming.............................................................. 5

3.1 User  programming list ..................................................... 6

3.2 Telephone number programming list ..................................... 7

3.3 Output switching menu ................................................... 8

3.4 Answering service menu (for remote controls) ....................... 9

3.5 Engineer  code enabilng menu ........................................... 9

3.6 User  code changing menu ............................................... 10

3.7 SIM card expiration menu ................................................. 11

3.8 Test call menu .............................................................. 12

3.9 SMS message editor menu................................................ 13

3.10 Voice message programming menu ...................................... 15

4.0 Cycle call stopping ............................................................. 15

5.0 Answering machine e remote control ..................................... 16

Alfanumeric coding table ..................................................... 19

DIRECTIVE R&TTE 99/05/EC COMPLIANCE

Informative note

Ministerial type-approval for transceivers and telecommunication terminals

was abolished on 8 April 2000.

The CT11-M terminal is designed and certified for PSTN (Public Switched

Telephone Network) use employing DTMF (Dual Tone MultiFrequency)

signalling. The terminal complies with the Pan-European Connection Directive

R&TTE 99/05/CE – ETSI TBR21 for use as a standalone terminal in an

analogue PSTN.

Refer to the technical instructions accompanying the product for possible

specific hardware and software programming.

Summary of Contents for CT10-M

Page 1: ...IS0171 AA 07 2003 CT10 M GSM telephone communicator CT11 M GSM PSTN telephone communicator User manual ...

Page 2: ...sage editor menu 13 3 10 Voice message programming menu 15 4 0 Cycle call stopping 15 5 0 Answering machine e remote control 16 Alfanumeric coding table 19 DIRECTIVE R TTE 99 05 EC COMPLIANCE Informative note Ministerial type approval for transceivers and telecommunication terminals was abolished on 8 April 2000 The CT11 M terminal is designed and certified for PSTN Public Switched Telephone Netwo...

Page 3: ...FAST BLINKING TRANSMITTING 1 2 DESCRIPTION OF THE KEYS OK key used to confirm parameter modifications during programming and to start listening to and recoding messages Arrow keys used to scroll the programming menu and select the functions to be programmed EXIT key used to quit the programming menus Number pad keys for entering access code telephone numbers and selecting programming parameter val...

Page 4: ... AND NETWORK BATTERY FAILURE WARNING LEDS 2 2 VIEWING SYSTEM STATUS The SYSTEM STATUS menu can be accessed in any condition without entering a code Simply press C followed by a number key from 1 to 8 Either press to quit the menu or wait for the time out one minute IN Not QUITTED IN 1 alarm memory IN 2 alarm memORY IN BUTTONS TO PRESS LANGUAGE FRENCH GERMAN DISPLAY TRANSMETTEUR GSM RTC COMMUNICATO...

Page 5: ...ATION IF ANOMALY PRESENT WARNING CT11 M only CYCLES WITH ANOMALIES TOTAL CYCLES CALLS WITH ANOMALIES GSM CALLS MADE CALLS WITH ANOMALIES PSTN CALLS MADE NUMBER OF NO FIELD COVERAGE FAILURES N OF DISCONNECTION FAILURES BETWEEN GSM MODULE AND CT10 M CT11 M OR MISSING SIM CARD NUMBER OF NO PSTN LINE FAILURES CT11 M COUNTER RESET COMMAND ACTIVE ONLY WHEN FAILURE AND ANOMALY CONDITIONS HAVE BEEN RESTOR...

Page 6: ...de because the system is being supervised at the time 3 1 USER PROGRAMMING LIST Enter the 6 digit user code x x x x x x default 111111 USER MENU TELEPHONE NR USER MENU SWITCH OUTPUT USER MENU CODE CHANGING USER MENU CALL TEST USER MENU SMS MESSAGE USER MENU VOCAL MESSAGES USER MENU ANSWERING PROG USER MENU ENGINEER ENABLED USER MENU SIM CARD 6 7 11 12 14 pag pag pag pag pag 8 pag 10 pag 9 pag 8 pa...

Page 7: ... 9 to enter the required telephone number digits Press to include a 2 seconds pause during dialling To edit a telephone number position the cursor on the digit to be changed by pressing and enter the new digits Press C to delete the entire number Press 0 for at least one second to enter the international prefix CT10 M only Press 7 PQRS for at least one second to enter Press 9 WXYZ for at least one...

Page 8: ... to its original condition to select the outputs to confirm the output to switch to return to the output switching menu to confirm the selection The current output status is displayed Press C to change user MENU SWITCH OUTPUT SWITCH OUTPUT OUTPUT NR 3 SWITCH OUTPUT OUTPUT NR 4 SWITCH OUTPUT OUTPUT NR 5 OUTPUT NR 5 DISABLED OUTPUT NR 5 ENABLED SWITCH OUTPUT OUTPUT NR 5 ...

Page 9: ...NU for remote controls This procedure can be used to activate the answering service function permitting a connection between the caller and the communicator to operate remote controls to confirm The answering service function will be activated also if the skip outgoing message is automatically activated The number of rings on CM10 M are only indicative USER MENU ANSWERING PROG ANSWERING PROG OFF A...

Page 10: ... customise the USER access code default 111111 to confirm the entered code Enter the new 6 digit programming code by means of the number keys 0 9 Re enter the new code by means of the number keys 0 9 to reconfirm the entered code USER MENU CODE CHANGING NEW CODE NEW CODE CODE CONFIRM ...

Page 11: ...d before programming the SIM card expiration ENGINEER MENU SIM CARD SIM CARD EXPIRE mm aa to confirm Enter the 4 digits corresponding to the month and year of expiration by means of the numeric keys 0 9 You are advised to enter the month before that of actual expiration of the SIM card SIM CARD EXPIRE 03 04 EXAMPLE EXAMPLE SIM CARD EXPIRATION MARCH 2004 The SIM card expiration text message will be...

Page 12: ...ling 12 in DTMF from the telephone which is receiving the call The test call will not be made if the 12th telephone number is not programmed CT11 Monly to select the telephone network Press the communciator will make one call to the 12th number repeating the basic voice message three times The test call cycle can be barred by entering dial 12 in DTMF from the telephone which is receiving the call ...

Page 13: ...IRATION WARNING CT10 M SIM CARD EXPIRATION The message text for each ALARM FAILURE SIM CARD EXPIRATION event can be freely edited maximum 40 characters per message to select actions to confirm selection to confirm message selection to select messages Enter the number by means of the number keys 2 9 by pressing the button corresponding to one two three or four times according to the position of the...

Page 14: ...HAN 16 CHARACTERS An arrow will appear after the last character if the message is more than 16 characters long Press and to see the rest of the message Reading a text message Deleting a text message READING SMS 02 READING SMS 03 READING SMS 04 FALLING sim CT10 M MESSAGE SMS READING SMS READING SMS 01 CANCEL SMS 01 CANCEL SMS 02 CANCEL SMS 03 CANCEL SMS 104 FALLING sim CT10 M MESSAGE SMS DELETE SMS...

Page 15: ...nput 2 alarm 5 sec Output U3 on 5 sec Output U3 off 5 sec Output U4 on 5 sec Output U4 off 5 sec Output U5 on 5 sec Output U5 off 5 sec TECHNICAL FAILURE 5 sec TELEPHONE FAILURE CT11 M only 5 sec Scroll the list and select the message to be recorded or played to confirm the selection Press to start recording The remaining time will decrease on the display EXAMPLE to confirm selection USER MENU VOC...

Page 16: ...the call cycle in progress is barred when the TC switched to ON The call cycle can also be barred locally by means of the keypad by entering a valid code user code or ENGINEER code where enabled BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING BASIC MESSAGE SPECIFIC MESSAGE BEEP WAIT FOR BARRING 10 s 5 s 0 5 s 5 s 10 s 5 s 0 5 s 5 s 10 s 5 s...

Page 17: ...utput The communicator will give priority to an alarm triggered during the remote control procedure No on off commands will be accepted and a WRONG CODE BEEP will be output Hang up Each remotely controllable output can be programmed as maintained or timed Status changes follow the command if the output is maintained The on command 1 will activate the output and the timer while the off command 0 wi...

Page 18: ...CODE RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT RECEIVED CODE DIGIT BEEEEP WRONG CODE 1 2 5 RECEIVED 0 5s BEEP Send code 5 3 3 Send code corresponding to output to be switched OR OR repeatprocedurefrompoint 2 RECEIVED 0 5s BEEP 4 4 5 OR 0 Send code 1 on or 0 off 5 1 OR 0 5s 3BEEPS COMMAND DONE ASSOCIATED VOICE MESSAGE More than one output can be switched or the...

Page 19: ...11 M 1 9 ALPHANUMERIC CODING TABLE T U V 8 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PQRS 8 TUV 9 WXYZ Ø 1 A B C 2 D E F 3 G H I 4 J K L 5 M N O 6 P Q R S W X Y Z 7 9 KEY NUMBER OF TIME TO PRESS KEY 1 2 3 4 5 6 7 8 WHITESPACE 0 ...

Page 20: ... CT11 M 2 0 ELKRON SPA Via Carducci 3 10092 BEINASCO TO TEL 011 3986711 FAX 011 3499434 EMAIL info elkron it EMAIL Assistenza Tecnica stac elkron it UNI EN ISO9001 UNI EN ISO14001 CERTIFICAZIONI DI QUALITA AZIENDALE ...

Reviews: