background image

www.ellia.com 

US: 1-248-863-3160  CAN: 1-888-225-7378 

IB-ARM504

TROUBLESHOOTING

Problem

Possible cause

Solution

No mist

Power supply is not connected

Plug the adapter in and press the power button

Insufficient water

Refill the water reservoir

Water is exceeding the max fill line

Dump the excess water out of the reservoir

The ultrasonic membrane is clogged with 

essential oil buildup

Clean the membrane by following the 

aforementioned instructions

CLEANING AND CARE

1.  Before cleaning the unit, turn the power off and make sure 

the adapter is unplugged from the diffuser and outlet.

2.  Remove the outer cover from the base. Next, remove the 

inner cover.

3.  Carefully pour any remaining water and essential oil 

out of the reservoir, from the drain side, opposite the 

air outlet. Be sure not to empty the reservoir near the air 

outlet in order to avoid malfunction.

To clean the surface

Clean the surface of your diffuser with a soft, damp cloth as 

often as needed.

To clean the reservoir and ultrasonic membrane

We recommend wiping the reservoir with a soft, damp cloth 

at least every 2 weeks. 

NOTE:

 Depending on your usage, and the amount of essential 

oil you use, you may want to clean the reservoir and 

ultrasonic membrane more frequently for best performance.

For the most-thorough clean, pour a 50/50 mixture of 

vinegar and water into the reservoir, and let it soak for 

5 minutes. Clean reservoir walls, base, and ultrasonic 

membrane with a soft-bristle brush (not included) and rinse. 

NEVER touch the ultrasonic membrane with your fingers, as 

the natural oils in your skin can damage the membrane. 
Clean and dry the unit before extended periods of 

inactivity.

ESSENTIAL OILS AND PETS

Always exercise caution when using essential oils around 

pets. Keep all essential oils and aromatherapy products (like 

diffusers) out of the reach of pets. Keep open bottles away 

from pets to avoid internal consumption. Not recommended 

for topical use on pets, as they have a strong sense of 

smell and cannot get rid of the oil if they don’t like it or it is 

disturbing them. When diffusing essential oils around pets, 

always diffuse in a well-ventilated area and leave an option 

for them to remove themselves from the space, such as 

leaving a door open. Every animal is different, so carefully 

observe how each animal responds when introducing an 

essential oil for the first time. If irritation occurs, discontinue 

the use of the essential oil. We recommend seeking medical 

attention if ingestion of essential oil occurs.

5–7

Summary of Contents for ARTISAN ARM-504

Page 1: ...at is dispersed evenly into the air delivering a natural aroma to enhance your mood White light Gentle glow creates a peaceful environment Runtime Up to 6 hours of continuous runtime or 12 hours of intermittent runtime Soothing humidity Alleviates dry air Auto shutoff protection When the reservoir is empty the unit will shut off automatically Reservoir capacity 150 ml Adapter voltage 100 240V 50 6...

Page 2: ...TIAL OILS Visit us online to stock up on your favorite Ellia Essential Oils including our single notes and signature blends www ellia com Aroma mist Your diffuser has 2 mist options Press once for continuous mist which will run for up to 6 hours Press again for intermittent mist 30 seconds on 30 seconds off which will run for up to 12 hours Press a third time to turn the mist off Press and hold to...

Page 3: ... oil you use you may want to clean the reservoir and ultrasonic membrane more frequently for best performance For the most thorough clean pour a 50 50 mixture of vinegar and water into the reservoir and let it soak for 5 minutes Clean reservoir walls base and ultrasonic membrane with a soft bristle brush not included and rinse NEVER touch the ultrasonic membrane with your fingers as the natural oi...

Page 4: ...y with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules and CAN ICES 3 B NMB 3 B These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radi...

Page 5: ...ar heat sources such as a stove Always keep the cord away from high temperatures and fire To disconnect turn the unit off then remove the plug from the outlet DO NOT use outdoors For indoor use only NEVER cover the unit while it is operating If the cord sustains damage you must stop using this product immediately and contact Ellia Consumer Relations see Warranty section for Consumer Relations cont...

Reviews: