6. Wiring.

CAUTION

Be sure outlet box is properly grounded or that 

a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

Note

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

WARNING

:  If using this fan in a 

DAMP

 location, this fan 

must be connected to a supply circuit that is protected 
by a Ground Fault Circuit Interrupter (GFCI) to reduce 
the risk of personal injury, electrical shock or death.

When fan is secured in place on the hanging bracket, 
electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

Since this fan does not come with a light kit, you will 
need to cap off the 

BLUE 

wire with a wire connector (as 

shown with arrow in diagram). [

Note

: If you elect to 

purchase a light kit for the fan, the 

BLUE

 wire from the 

fan must be connected to the 

BLACK

 wire from the 

ceiling instead.]

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

IN ORDER TO WIRE WALL CONTROL

, remove existing wall 

switch. Wire the

 WALL CONTROL

 with wire connectors provided 

as shown in 

diagram at right.

* Wrap each wire connector separately with electrical tape as an 
extra safety measure. Gently push wires and taped wire 
connectors into outlet box.

WARNING

:

 

CONNECT WIRES IN THE FOLLOWING ORDER ONLY!

WARNING

: Turn off circuit breakers to current fixture from 

breaker panel and be sure switch is turned to the OFF position.

Connect 

GREEN

 ground wire to ground from house or directly 

to one of the screws from the outlet box.

Connect one 

BLACK

 wire from wall control to 

BLACK

 (hot) lead 

wire from house. Connect second 

BLACK 

wire from wall control 

to 

BLACK

 load wire to fan.

Attach wall control to outlet box and secure with screws from 
original wall switch. Attach front plate to wall control using 2 
screws provided in the wall control.

black (OUT to fan)

green

black

(AC IN from

breaker box)

black

(TO POWER supply)

(wiring for wall control)

black

green/

green/

bare 

bare 

 ground

 ground

green/

bare 

 ground

outlet box

wall

control

plate

Modifications not approved by the party responsible for compliance 
could void the user's authority to operate the equipment.

*NOTE: This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
        *      Reorient or relocate the receiving antenna. 
        *      Increase the separation between the equipment and receiver. 
        *      Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

wire

connector

black

black

white

white

blue

black supply wire

ground

 (green

or bare)

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

Summary of Contents for COL72BP6

Page 1: ...mated Learning Process Activating Code pgs 8 9 Testing Your Fan pg 9 Troubleshooting pg 10 Parts Replacement pg 10 Warranty pg 10 PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE Installation Guide For Models COL72BP6 COL72ESP6 COL96BP6 COL96ESP6 net weight of fan 34 43 lb 15 62 kg COL72BP6 COL72ESP6 35 27 lb 16 00 kg COL96BP6 COL96ESP6 F P O F P O For Placement Only For Place...

Page 2: ...ing this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL Canada or ETL USA listed and marked suitable for use with the model fan you are installing Swi...

Page 3: ...piece c downrod and hanging ball 1 piece d motor housing 1 piece e switch housing plate 1 piece f switch housing cap 1 piece g yoke cover 1 piece h blade arm 6 pieces i blade 6 pieces j safety cable already attached to motor 1 piece k canopy cover in hardware pack 1 piece l remote control transmitter 1 piece m wall control plate and decor covers 5 separate pieces n hardware packs IMPORTANT REMINDE...

Page 4: ...bracket to outlet box using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the hanging ...

Page 5: ... this will keep the wires together when threading them through the downrod Locate canopy cover in hardware pack Loosen yoke set screws and nuts at top of motor housing Remove pin and clip from motor housing yoke Slide downrod through canopy canopy cover and yoke cover Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cable and electrical wires through downrod ...

Page 6: ...ng bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood ...

Page 7: ...urrent fixture from breaker panel and be sure switch is turned to the OFF position Connect GREEN ground wire to ground from house or directly to one of the screws from the outlet box Connect one BLACK wire from wall control to BLACK hot lead wire from house Connect second BLACK wire from wall control to BLACK load wire to fan Attach wall control to outlet box and secure with screws from original w...

Page 8: ...attachment screws and washers and 18 decorative nuts in hardware packs Place blade arm on TOPSIDE of blade aligning holes in blade arm with holes in blade as shown Be sure to note label on blade indicating THIS SIDE UP and turn blade so that label faces up With fingers insert 3 blade attachment screws along with washers from the TOPSIDE of blade and 3 decorative nuts from UNDERSIDE of blade making...

Page 9: ...rews for later use Remove 1 screw from fitter plate on underside of motor and partially loosen the other 2 screws Align slotted holes in center of switch housing plate with loosened screws in fitter plate allowing molex plugs from motor housing to come through hole in middle of switch housing plate Twist switch housing plate to lock Re insert screw that was removed and secure all 3 screws Align ho...

Page 10: ...ith fan in order to properly function I OFF ON II III IV V VI I II IV VI III V reverse reverse Wall Control Remote Control 10 Automated Learning Process Activating Code cont Remove battery cover on back side of remote control transmitter Install 12 volt battery provided in transmitter and wall control IMPORTANT Store the transmitter away from excess heat or humidity To prevent damage to transmitte...

Page 11: ...tion of finishes or other parts due to time or exposure to salt air is specifically exempted under this warranty Neither Craftmade Ellington nor the manufacturer will assume any liability resulting from improper installation or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limit...

Page 12: ...a de encendido Pág 8 Proceso de aprendizaje automático Activar el código Págs 8 9 Verificación del funcionamiento del ventilador Pág 9 Localización de fallas Pág 10 Piezas de repuesto Pág 10 Garantía Pág 10 peso neto del ventilador 15 62 kg 34 43 lb COL72BP6 COL72ESP6 16 00 kg 35 27 lb COL96BP6 COL96ESP6 IMPRESO EN CHINA LEER ESTAS INSTRUCCIONES Y GUARDARLAS PARA UTILIZACION FUTURA Guía de instala...

Page 13: ...nectores para cable que se debe usar ADVERTENCIA Si va a utilizar este ventilador en un lugar HÚMEDO hay que conectar el ventilador a un circuito de alimentación que esté protegido por un Interruptor de Circuito de Falla de Tierra GFCI por sus siglas en inglés para reducir el riesgo de daño corporal descarga eléctrica o la muerte 5 Los diagramas eléctricos son únicamente para referencia Los juegos...

Page 14: ...ntrol de pared placa y paneles decorativos 5 unidades distintas n paquetes de artículos de ferretería página 2 Abrir el empaque cuidadosamente Sacar los artículos del embalaje Sacar el motor y ponerlo en una alfombra o en el embalaje para evitar rayar el acabado Guardar la caja de cartón o el empaquetamiento original en caso de que tenga que mandar el ventilador para alguna reparación Comprobar la...

Page 15: ...si es necesario puede resultar en lesiones graves PRECAUCION Asegurarse de que la caja de salida esté conectada a tierra correctamente y que haya un conductor a tierra cable VERDE o pelado Instalar el soporte de montaje utilizando los tornillos originales las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalación en un techo abovedado colocar el s...

Page 16: ...e la cubierta decorativa en uno de los paquetes de artículos de ferretería Aflojar los tornillos de fijación del cuello y las tuercas en el cuello del bastidor del motor Quitar el perno y la clavija del cuello del bastidor del motor Pasar el tubo por la cubierta decorativa la tapa de la cubierta decorativa y la cubierta del cuello Nota Se tiene que voltear la tapa de la cubierta decorativa para qu...

Page 17: ...oporte de montaje ADVERTENCIA El no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda de otra persona para mantener sujeto la escalera y para que le suba el ventilador cuando usted ya esté preparado en la escalera para colgarlo Encontrar un punto de acoplamiento seguro se recomienda la...

Page 18: ...l lado Como una medida de seguridad adicional envolver cada conector para cable con cinta aisladora Delicadamente meter los conectores para cable dentro de la caja de salida ADVERTENCIA CONECTAR LOS CABLES SOLAMENTE EN EL ORDEN QUE SIGUE ADVERTENCIA Apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz esté APAGADO ...

Page 19: ...os y arandelas y 18 tuercas decorativas en uno de los paquetes de artículos de ferretería Colocar un brazo para el aspa en el LADO SUPERIOR del aspa alineando los agujeros del brazo para el aspa con los del aspa como se muestra Fijarse en la etiqueta en el aspa que indica ESTE LADO HACIA ARRIBA y voltear el aspa para que la etiqueta esté orientada hacia arriba Con los dedos introducir 3 tornillos ...

Page 20: ...ndido con los agujeros en la placa de la caja de encendido Volver a introducir los tornillos que se quitaron anteriormente y asegurar los 4 tornillos con un destornillador de estrella Phillips placa de la caja de encendido bastidor del motor placa de conexión conexiones tipo molex cubierta de la caja de encendido 10 Proceso de aprendizaje automático Activar el código control remoto control de pare...

Page 21: ...en el transmisor y el control de pared IMPORTANTE Guardar el transmisor lejos del calor excesivo o la humedad Para prevenir daño al transmisor sacar la batería si no se va a utilizar el transmisor por un tiempo extendido Botones de VELOCIDAD del ventilador 1 usar para controlar la velocidad del ventilador de 1 6 Botón de APAGADO 2 usar para apagar el ventilador Botón de REVERSA 3 usar para control...

Page 22: ...e marino bajo esta garantía Ni Craftmade Ellington ni el fabricante se harán responsables por lo que pasa por una instalación inadecuada o el uso impropio de este producto La compañía no se hará responsable en ningún caso de ningún daño emergente por incumplimiento de esta o cualquier otra garantía expresada o implicada en absoluto Esta limitación de daños emergentes no se aplicará en estados dond...

Reviews: