TABLE OF CONTENTS
Introduction ...................................................................... 2
Safety ............................................................................... 3
Start-up ............................................................................ 4
Quick Reference Diagram................................................ 5
Operation ......................................................................... 6
Brush Selection Guide / Specifications ............................ 7
Trouble Shooting.............................................................. 8
Tips .................................................................................. 9
Page 8
Elliott Soot Buster
TM-47
TM-47
Elliott Soot Buster
Page 1
TROUBLE SHOOTING HINTS
Condition
1. The pulsator stops in
tube but still pulsating.
2. The pulsator stops
vibrating in the tube.
Cause
1.1 Not enough air
pressure.
1.2 Check oil in lubricator.
1.3 Hose is caught.
1.4 Brush is off of air
pulsator.
Remedy
1.1 Wait until air pressure builds
back-up.
1.2 Refill if necessary.
Increase flow if required.
1.3 Turn off air supply and
dislodge hose.
1.4 Turn off air supply, rod out
brush and refit to air
pulsator.
2.1 Check remedies 1.1 to 1.4
2.2 Turn off air supply.
Switch on air supply sharply
as you pull back the
pulsator.
Turn off air and unscrew
pulsator from hose.
Squirt in plenty of oil.
Reconnect and turn on air
supply.