background image

 

Version 2.0.3 

February 13, 2006 

 

Installing the software and the drivers 

Please refer to the USB Analysis Software User's Manual for more information about the 
installation of the analysis software and the device driver. 

 

First data acquisition 

Before using the analyzer to make your first data acquisition, ensure that you 
have successfully completed every step needed to install the software and the 
drivers.  

Follow these steps to proceed with your first data acquisition: 

1.

 

Connect the USB analyzer to the analysis computer as demonstrated in the 
section entitled 

Connecting the analyzer to the analysis computer

. You must first 

have successfully installed the analysis software and drivers. 

2.

 

Run the analysis software and press keys 'Ctrl+R' (

Start Recording

). Refer to the 

chapter on 

Troubleshooting 

if the software indicates that no analyzer is 

connected. 

3.

 

Connect the USB device to be analyzed as discussed in the section entitled 

Connecting a device for analysis

. For greater safety, first connect a simple 

commercial device that you can understand easily. The number of valid 
transactions should increase slowly. You can save data acquisition after it has 
been recording for a few seconds by clicking the 

'Save

' button.  

4.

 

Congratulations! You have just used the analyzer to record your first data 
acquisition. You can now read the USB Analysis Software User's Manual to fully 
benefit from all the available power in the analysis software.  

USB Explorer 200 

User's manual 

Page 9 of 17 

Summary of Contents for USB Explorer 200

Page 1: ...Ellisys USB Explorer 200 Getting Started Guide Version 2 0 3 February 13 2006 Ellisys S rl ch du Grand Puits 38 CH 1217 Meyrin Geneva Switzerland www ellisys com support ellisys com...

Page 2: ...ata acquisition 9 Chapter 2 Frequently Asked Questions 10 General 10 Hardware 10 Chapter 3 Troubleshooting 11 Installation 11 Chapter 4 Technical data 12 Highlights 12 Applications 12 Requirements 12...

Page 3: ...two computers 6 Figure 2 Configuration with only one computer 6 Figure 3 Connecting only one Device Under Test 7 Figure 4 Wrong connection with more than one DUT 8 Figure 5 Correct connection with mor...

Page 4: ...ta sent by the analyzer and subsequently displays them in a simple easy to follow format Device Under Test A USB device that is going to be analyzed with the analyzer is called a device under test in...

Page 5: ...l speed and low speed USB 2 0 protocol analyzer that sends data using a high speed USB 2 0 connection The recommended configuration requires two computers one for communicating with the device under t...

Page 6: ...guration can only be used when the available computer is very powerful and when the device under test requires little processing power You must however ensure that two or more host controllers are ava...

Page 7: ...puter USB Explorer 200 Device Under Test Test computer Figure 3 Connecting only one Device Under Test To prevent problems which could arise from your cables length please follow the following instruct...

Page 8: ...lyzer is used to analyze multiple devices this analysis must necessarily involve a USB hub In this way you can ensure that all the devices to be analyzed are in fact below the analyzer You should be a...

Page 9: ...ssfully installed the analysis software and drivers 2 Run the analysis software and press keys Ctrl R Start Recording Refer to the chapter on Troubleshooting if the software indicates that no analyzer...

Page 10: ...n USB 2 0 extension card is used To obtain the best performance we highly recommend the use of two computers The analyzer records data using a USB 2 0 connection Do I need a USB 2 0 host controller No...

Page 11: ...y gain from all your analyzer s power Talk to your local dealer about getting a USB 2 0 host controller card I would like to connect the USB analyzer on a EHCI host controller but it seems that it doe...

Page 12: ...nsactions and transfers layers High level decoding of requests and descriptors Powerful display filters Exportation of analyzed data to several formats XML text raw etc Didactic display with reference...

Page 13: ...50 mA Indicators Power lights up when the analyzer in powered on Activity lights up in green when packets are detected in red when they are recorded Trigger lights up in green when a trigger is detect...

Page 14: ...he decoding engine and the firmware can be updated by software Product Warranty Two years limited warranty Ellisys reserves itself all rights to change product features and specifications without noti...

Page 15: ...emoved has not been handled or packaged correctly or has been sold as second hand This limited warranty only applies to the original customer of the product for so long as the original customer owns t...

Page 16: ...DISASTER PREVENTION SYSTEMS AND MEDICAL OR MEDICAL RELATED EQUIPMENT ELLISYS TOTAL LIABILITY UNDER THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED IS LIMITED TO REPAIR REPLACEMENT OR REFUND REPAIR REPL...

Page 17: ...f two 2 years Governing Law These conditions and terms shall be governed by and construed in accordance with the law of Switzerland Jurisdiction Venue The parties consent to the exclusive personal jur...

Reviews: