3.1
Setup for Link Layer, Device Framework,
Electrical, and Mass Storage Testing
To set up Examiner to test a device (or hub upstream port):
Connect as shown in the figure below, connecting a USB 2.0 cable from the Control Computer
hosting the Examiner application to the rear control port of the USB Explorer 280 that will
execute the Examiner’s tests.
Optionally, connect another USB 2.0 cable to the rear control port of an Explorer 280 Analyzer
in order to capture the traffic occurring between the PUT and Examiner. Examiner will control
the analyzer as well. If not connecting the analyzer, the USB 3.0 cabling may be installed direct
from Examiner to the PUT. If the analyzer is used, a second USB 3.0 cable is required between
the analyzer and the PUT as shown below.
The DC power supplies for the Examiner unit and the analyzer unit are
not shown in the Figure below, but are required.
Figure 3-2 Examiner Setup for Device (or hub upstream port)