To set up Examiner to test a host:
Connect as shown in the figure below, connecting a USB 2.0 cable from the Control Computer
hosting the Examiner application to the rear control port of the USB Explorer 280 that will
execute the Examiner’s tests.
Optionally, connect another USB 2.0 cable to the rear control port of an Explorer 280 Analyzer
in order to capture the traffic occurring between the port under test (PUT) and Examiner.
Examiner will control the analyzer as well. If not connecting the analyzer, the USB 3.0 cabling
may be installed direct from Examiner to the PUT. If the analyzer is used, a second USB 3.0
cable is required between the analyzer and the PUT.
Ensure USB30CV is loaded on the host under test.
The DC power supplies for the Examiner unit and the analyzer unit are
not shown in the Figure below, but are required.
Figure 3-3 Examiner Setup for Testing Host