32 of 124 |
Hardware Setup and Configurations
Ex
ami
n
er
U
se
r
G
u
ide
2.
Launch USB30CV on the host system under test, or the host system attached to the
upstream-facing port of the hub under test, as applicable.
3.
In USB30CV, select Link Layer Testing from the Select Test Suite box.
4.
Click Run on the USB30CV application.
The USB30CV advances to the first test to be supported (TD 7.06) and presents a message
such as shown below:
At this point, the user will execute the selected Examiner tests (in the Examiner application)
until Examiner displays a dialog instructing the user to initiate an action on CV, such as issuing
a Get Descriptor request as shown above.
For any further Examiner tests that require USB30CV initiation of host-side actions (such as
sending the Get Descriptor request above), Examiner will provide a dialog instructing the user
to initiate this action on USB30CV.
To run USB30CV in Debug Mode:
Debug mode on the USB30CV application allows the user to specify
which tests are to be run.
1.
Select Debug from the Select Test Mode option on the USB30CV application.
2.
Select one (or more) or check boxes associated with the tests desired to be executed in
the Select Test Box on USB30CV application.
3.
Click Run on the USB30CV application.
4.