11.5 Tracking Link State Changes
LTSSM state changes are tracked in the
USB 3.x Overview
using color-coded vertical bars at the far-left of the view
that indicate particular link state changes. These link state changes are coordinated with like color-coding in the
Instant Timing
and
Instant Link State
panes.
The table below describes the link state changes and related color-coding:
GRAY Line
Power ON/OFF transition
ORANGE Line
Transition to LFPS and link training sequences
GREEN Line
Transition to U0
BLUE Line
Transition to low power states
11.6 Synchronization to Other Panes
Each
Overview
is synchronized to other views in order to give the user a comprehensive understanding of the traffic
captured. Synchronizations are available to the
Instant Timing
,
Raw Data
,
Instant Link State
, and
Details
panes.
Synchronization to the
Instant Timing
pane can be disabled in the
Instant Timing
pane toolbar, but is enabled by
default.
To force the selected event in an
O
Overview
to display in
Instant Timing
:
1. Right-click in the desired
Overview
.
2. Select Show in Instant Timing view.
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......