142 of 157 |
Analyzer Recording Activity Menu
User Guide
The table below describes information fields in the
General
tab for Upstream and Downstream links:
Capture
Indicates the total of data captured in Mbytes.
Throughput
Indicates the instantaneous throughput in MByte/s.
Phy Error Ratio
Indicates the ratio of all characters captured to characters identified by the Analyzer as having
10b coding or disparity errors.
Link Error Ratio
Indicates the ratio of link items captured with errors to the total count of link items. Errors
can be CRC errors or symbols error inside the link item. A link item can be a training ordered
set, a link command, a header packet or a data payload packet.
To reset throughput and error indications:
1. Select Reset Throughputs to reset cumulative throughput calculations to zero.
Or
Select Reset Errors to reset cumulative error calculations to zero.
The selected indication is reset to zero.
19.2 Performance
The
Recording Activity - Performance
tab provides a real-time graphical indication of throughput for upstream and
downstream links, as well as an aggregate throughout indication.
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......