Analyzer Recording Activity Menu
| 145 of 157
Ellisys USB Explorer 350
Capture
Indicates the total of data captured in MBs.
Throughput
Indicates three different data throughput metrics as described below:
Last indicates last-calculated throughput and packet rate.
Min indicates the low-water throughput and packet rate.
Max indicates the high-water throughput and packet rate.
Errors
Indicates error count information as described below:
Phy indicates a count of 10b and disparity errors.
Link indicates a count of link-layer errors.
Error Ratio
Indicates error ratio information as described below:
Phy indicates the ratio of all characters captured to characters identified by the Analyzer
as having 10b coding or disparity errors.
Link indicates the ratio of link items captured with errors to the total count of link items.
Errors can be CRC errors or symbols error inside the link item. A link item can be a
training ordered set, a link command, a header packet or a data payload packet.
To reset throughput and error indications:
1. Select Reset Throughputs to reset cumulative throughput calculations to zero.
Or
Select Reset Errors to reset cumulative error calculations to zero.
The selected indication is reset to zero.
19.4 Options
The
Recording Activity - Options
tab provides display and error tracking options. Options available are shown below:
Options available in the
Options
tab are described below:
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......