Exerciser User Interface
| 37 of 157
Ellisys USB Explorer 350
CConfigurations
The Configurations section is populated using the AAdd button in this section, and configured for a
particular object by selecting one or more check boxes in the Capabilities section. The object
highlighted in this section is what will be used by the Exerciser.
Add
Add a new capability
Delete
Delete the selected capability
Move Up
Move the selected capability up
Move Down
Move the selected capability down
Capabilities
The Capabilities section is populated using the Add button in this section, and configured for a
particular object using the Capabilities Properties section.
Add
Add a new capability
Delete
Delete the selected capability
Move Up
Move the selected capability up
Move Down
Move the selected capability down
Capability
Properties
The Capability Properties section is populated using the various drop-down menus, check boxes,
and text-entry fields in this section.
Type
Provides selections for Source Capabilities Power Data
Object (PDO) for Fixed Supply, Battery, Variable Supply, or
Reserved.
Description
Allows the user to assign a text string (name) to a
particular capability property
Raw
Hex input and display. Populated by entries made by the
user in this section. Can be used to populate reserved
fields with non-default values. May also be used to define
the full PDO in lieu of drop-down and check-box selections.
Fixed Supply
Selects Fixed Supply as the PDO
Voltage
Allows the user to specify a value in the Voltage field of the
Fixed Supply PDO
Max Current
Allows the user to specify a value in the Maximum Current
field of the Fixed Supply PDO
Peak Current
Allows the user to specify a value in the Peak Current field
of the Fixed Supply PDO
Dual-Role Power
Sets the Dual-Role Power field in the PDO
Externally Powered
Sets the Externally Powered field in the PDO
Data Role Swap
Sets the Data Role Swap field in the PDO
USB Capable
Sets the USB COMM Capable field in the PDO
USB Suspend Capable
Sets the USB Suspend Supported field in the PDO
Battery
Selects Battery as the PDO
Max Power
Allows the user to specify a value in the Maximum Power
field of the Battery PDO
Min Voltage
Allows the user to specify a value in the Maximum Voltage
field of the Battery PDO
Max Voltage
Allows the user to specify a value in the Maximum Voltage
field of the Battery PDO
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......