Exerciser User Interface
| 39 of 157
Ellisys USB Explorer 350
CConfigurations
The Configurations section is populated using the AAdd button in this section, and configured for a
particular object by selecting one or more check boxes in the Capabilities section. The object
highlighted in this section is what will be used by the Exerciser.
Add
Add a new capability
Delete
Delete the selected capability
Move Up
Move the selected capability up
Move Down
Move the selected capability down
Capabilities
The Capabilities section is populated using the Add button in this section, and configured for a
particular object using the Capabilities Properties section.
Add
Add a new capability
Delete
Delete the selected capability
Move Up
Move the selected capability up
Move Down
Move the selected capability down
Capability
Properties
The Capability Properties section is populated using the various drop-down menus, check boxes,
and text-entry fields in this section.
Type
Provides selections for Sink Capabilities for Fixed Supply, Battery,
Variable Supply, or Reserved.
Description
Allows the user to assign a text string (name) to a particular
capability property
Raw
Hex input and display. Populated by entries made by the user in this
section. Can be used to populate reserved fields with non-default
values. May also be used to define the full RDO in lieu of drop-down
and check-box selections.
Fixed Supply
Selects Fixed Supply as the Request Data Object (RDO)
Voltage
Allows the user to specify a value in the Voltage field of the Fixed
Supply RDO
Op Current
Allows the user to specify a value in the Operating Current field of
the Fixed Supply RDO
Dual-Role Power
Sets the Dual-Role Power field in the RDO
Externally Powered
Sets the Externally Powered field in the RDO
Data Role Swap
Sets the Data Role Swap field in the RDO
USB Capable
Sets the USB COMM Capable field in the RDO
Higher Capability
Sets the USB Suspend Supported field in the RDO
Battery
Selects Battery as the RDO
Op Power
Allows the user to specify a value in the Operating Power field of the
Battery RDO
Min Voltage
Allows the user to specify a value in the Maximum Voltage
field of the Battery PDO
Max Voltage
Allows the user to specify a value in the Maximum Voltage field of
the Battery PDO
Variable Supply
Selects Variable Supply as the PDO
Op Current
Allows the user to specify a value in the Operating Current field of
the Variable Supply PDO
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......