46 of 157 |
Exerciser User Interface
User Guide
BIST Tester
Mode
Receiver
The Exerciser sends BIST Receiver Test Frames with 1024 bits of
PRBS payload.
Transmitter
The Exerciser sends a BIST Transmitter Test Frame to initiate BIST
Transmitter mode in the far-end transmitter.
Test Data
The Exerciser sends the Test Data frame with BIST Test Data BDO,
Data Objects = 7, and 192 bits (28 bytes) of PRBS data. BMC
required.
Eye Pattern
The Exerciser sends a continuous string of bits (PRBS-8). This
produces a signal that will allow measurement of the eye pattern and
of the spectrum mask.
Carrier
Mode 0
The Exerciser sends a continuous string of "0"s.
Mode 1
The Exerciser sends a continuous string of "1"s.
Mode 2
The Exerciser sends a continuous string of alternating "1"s and “0”s.
BMC required.
Mode 3
The Exerciser sends a continuous string of sixteen "1"s, followed by
sixteen “0”s, followed by sixteen “1”s, etc.
Start Test
Initiates the selected BIST Mode.
Hard Reset
The Exerciser sends a Hard Reset (used to exit the active BIST
Mode).
Recipient
Specifies the recipient device type (SOP, SOP’, SOP”).
Errors
Provide a running count of errors detected in Transmitter or Receiver
BIST modes. Initialized to zero at test start.
Summary of Contents for USB Explorer 350
Page 1: ...Ellisys USB Explorer 350 User Manual Version 0 83 October 30 2015...
Page 36: ...36 of 157 Exerciser User Interface User Guide Figure 13 Source Capabilities Interface...
Page 41: ...Exerciser User Interface 41 of 157 Ellisys USB Explorer 350 Figure 16 Edit VDM Modes...
Page 61: ...Examiner User Interface 61 of 157 Ellisys USB Explorer 350 Figure 31 Examiner Settings Tab...
Page 86: ...86 of 157 Managing Analyzer Recordings User Guide...
Page 138: ...138 of 157 Analyzer Protocol Error Verifications User Guide...
Page 157: ......