Elma 117 - 118
Page 56
600
Ω
WITH CONTINUITY BEEPER
RANGE ACCURACY
600.0
Ω
2.0%+8D
1)
CONTINUITY BEEPER RESPONSE: < 100
μ
S
OPEN CIRCUIT VOLTAGE: 0.4VDC TYPICAL
Audible Threshold: between 10
Ω
and 300
Ω
1)
ADD 40D TO SPECIFIED ACCURACY WHILE READING IS BELOW 20% OF RANGE
Frequency
Voltage
Range
SENSITIVITY
(SINE RMS)
RANGE
6.000V
4V
10HZ ~ 30KHZ
60.00V
30V
10HZ ~ 1KHZ
600.0V
60V
10HZ ~ 1KHZ
Accuracy: 0.5%+4d
Max display: 9999 counts
AC Voltage
RANGE ACCURACY
50HZ / 60HZ
6.000V, 60.00V
1.5% + 5D
600.0V
2.0% + 5D
50HZ ~ 500HZ
6.000V, 60.00V
2.0% + 5D
600.0V
2.5% + 5D
CMRR
: >60DB @ DC TO 60HZ, RS=1K
Ω
HI-Z ACV INPUT IMPEDANCE:
5M
Ω
, 90PF NOMINAL
AutoCheck
TM
Lo-Z ACV input impedance:
Initially 1.6k
Ω
, 90pF nominal;
Impedance increases significantly as display voltage increases from 50V (typical). Typical
impedances vs display voltages for reference are:
15k
Ω
@ 100V
100k
Ω
@
300V
210k
Ω
@
600V
AutoCheck
TM
ACV Threshold:
> 2VAC (50/60Hz) nominal
True RMS model BM118 Crest Factor:
< 1.6 : 1 at full scale & < 3.3 : 1 at half scale