Operating faults
100
BA_Elmasolvex_VA_EN_Vers.05.2018
© Elma Schmidbauer GmbH
11.3.1
Cleaning deflagration protection
If liquid discharges at the bottom connection for venting the
media tanks (
Fig.11.3.1.1.G
), the deflagration protection should
be cleaned afterwards.
1. Remove the two 3 mm Allen screws (
Fig. 11.3.1.1.A
) on the
bottom of the cleaning machine.
2. Remove the four 3 mm Allen screws (
Fig. 11.3.1.2.B
) on
the rear side of the cleaning machine and remove the cover
(
Fig. 11.3.1.2.C
) of the service opening.
3. Detach the two tube connections (
Fig. 11.3.1.2.E
) by pulling
on the respective tube and simultaneously pressing on the
grey ring (
Fig. 11.3.1.3.F
).
4. Remove the deflagration protection (
Fig. 11.3.1.3.D
) and
drain the residual liquid present.
5. Let the deflagration protection dry (leave for approx.
30 minutes in the removed condition or blow out with
compressed air).
6. Reinstall the deflagration protection in the cleaning machine
in reverse order (Fig. 11.3.1.1.A).
Fig. 11.3.1.1 Bottom view of cleaning machine with screw connection
Procedure
G
A