Appendix 1: Activated carbon unit
© Elma Schmidbauer GmbH
BA_Elmasolvex_VA_EN_Vers.05.2018
107
14.2
Filling / Installation / Commissioning
The activated carbon cartridges are not filled when delivered.
Proceed as follows for the filling:
Detach the retaining plate (C) from the base plate (J).
Open the screw plugs (H) of the filter cartridges and fill these
using the funnel: 1 packet each of the supplied activated carbon
granulate per filter cartridge.
Close the screw plugs and reattach the retaining plate.
The base plate can either be placed on the plastic feet or wall-
mounted.
Benefit for wall mounting: the condensate separator can be
unscrewed for emptying without having to detach the retaining
plate (
Fig.14.2.1.C
) from the base plate.
For wall mounting, first fasten the base plate (floor bracket / feet
upwards) using the supplied mounting material. Attach the
retaining plate to the base plate (see
Fig. 14.2
.
1
).
Fig. 14.2.1 Activated carbon filter in wall mounting position
1. Cut the exhaust air tubes included in the scope of delivery
to length and put these on the quick couplings (A and B).
2. Insert the quick couplings (A and B) into the corresponding
mating pieces of the activated carbon unit so that these are
securely engaged.
Filling the activated
carbon cartridges
Installation
Connecting exhaust
air tubes
C
L
B
J
A
HH