Appendix 1: Activated carbon unit
110
BA_Elmasolvex_VA_EN_Vers.05.2018
© Elma Schmidbauer GmbH
Unclip the quick couplings (A / B) of the exhaust air tubes from
the connections on the activated carbon unit.
Detach the retaining plate (C) from the base plate (J).
Open the screw plugs (
Fig. 14.1.1.H
) of the activated carbon
cartridges one after the other.
Empty the used activated carbon granulate.
Place the retaining bracket with the condensate separator and
the activated carbon cartridges turned over on a work surface.
Fill the required quantity of new activated carbon granulate
using the funnel.
Close the screw plug.
Reattach the retaining plate to the base plate.
Mark a new label and attach it so that it is visible to the
activated carbon unit.
14.3.3
Changing PE filter
There is a total of 6 PE filters in the activated carbon unit. The
filters are available as a set and all four must be changed.
Elma order number 105 3821
Annually or depending on the operating conditions: If the
required cleaning time gradually becomes longer and/or if an
appropriate warning message is shown on the display.
Unscrew the outer PE filter (Fig.
14.3.3.1.M
) from the activated
carbon cartridge.
Wrap Teflon sealing tape around the thread of the new PE filter.
Screw in the new PE filter hand tight.
Unscrew the condensate separator (see also
Chapter 14.3.1
Emptying condensate separator
) from the holder.
Unscrew the used PE filter (
Fig. 14.3.3.1.O
) from the mounting
thread.
Wrap Teflon sealing tape around the thread of the new PE filter.
Screw in the new PE filter hand tight.
Screw the condensate separator back into the holder tightly.
It is recommended to carry out the replacement of the PE filters
in the activated carbon cartridges in the course of replacing the
activated carbon granulate.
Detach the retaining plate (C) from the base plate (J).
Unscrew the activated carbon cartridge (see also
Chapter
14.3.2
Replacing activated carbon granulate
) from the holder.
Empty the used activated carbon granulate.
Procedure
Order number
Interval
Changing outer
PE filter
Replacing PE filter in
the condensate
separator
Replacing PE filters in
activated carbon
cartridges