Important safety instructions
© Elma Schmidbauer GmbH
BA_Elmasolvex_VA_EN_Vers.05.2018
7
Keep the installation area, case and controls dry. Protect
against ingress of moisture. Unplug the mains plug during
filling, maintenance and care of the cleaning machine, suspicion
that liquid has penetrated, operating faults and after use.
The cleaning machine must only be opened by trained staff.
The cleaning machine must be installed at a dry and sufficiently
ventilated place for the extraction of vapours of the cleaning
and rinsing media from the area of the media tanks filled with
these media.
The installation surface must be smooth and flat for application-
related reasons.
The maximum permitted ambient temperature is 30 °C.
The intended exhaust air equipment (exhaust air pipes with
maximum length 5 m or activated carbon unit) for them must be
installed at the ventilation openings (cleaning machine rear
side) before start-up.
Only permitted media must be used in this cleaning machine.
Observe the information in
Chapter 8
.
The cleaning machine is only permitted to be operated with the
connected and correctly filled 4 original media tanks included in
the scope of delivery (see
Chapter 4.4
).
Ignitable solvent vapours can escape in the case of improper
operation (without exhaust air connection) and during
replacement of the cleaning and rinsing media.
Smoking and open ignition sources in the cleaning machine
surroundings, particularly in the immediate vicinity of the zone
marked with the appropriate danger symbol are therefore
prohibited.
Strictly observe the safety instructions specified in this manual
to prevent such hazards.
In the event of liquid discharge from the cleaning machine
(amount > droplets), the cleaning machine must no longer be
operated for safety reasons.
Maximum one day's requirement of the solvents used is
permitted to be stored in the surroundings of the cleaning
machine at a minimum distance of 3 m from the cleaning
machine.
Observe the specified safety measures in the safety data
sheets of the respective media used. This also applies with
respect to solvent vapours.
Depending on the operating time of the cleaning machine,
surfaces, particularly the inner wall of the drying chamber, can
become very hot (max. approx. 65 °C).
The black Elma basket holder (Art. No. 105 3905) is delivered
as standard. It is used for attaching electropolished baskets,
baskets made from stainless steel, plastic-coated baskets and
plastic baskets. Only electropolished baskets may be used in
the blue Elma basket holder (Art. No. 105 3162 Accessories).
Prevention of
electrical accidents
Installation
Ambient temperature
Exhaust air
equipment
Media (cleaning /
rinsing solutions)
Fire and explosion
hazard
Hazards from
solvents
Hot surfaces
Cleaning basket