Operating faults
88
BA_Elmasolvex_VA_EN_Vers.05.2018
© Elma Schmidbauer GmbH
•
Correct media tanks fill levels
•
Switch off cleaning machine and
restart: Contact Service if the fault
persists.
202
Abortion
Critical fault!
Pressure measurement
defective.
Program has not been
ended.
Pressure measurement
failure:
Sensor or electronics fault.
Check the following possibilities:
•
Switch off cleaning machine and
restart: Contact Service if the fault
persists.
203
Abortion
Critical fault!
Temperature
measurement defective.
Program has not been
ended.
Temperature measurement
failure.
Check the following possibilities:
•
Switch off cleaning machine and
restart: Contact Service if the fault
persists.
204
Abortion
Critical fault!
Overfilling level filling
level sensor defective.
Program has not been
ended.
Plausibility error (working
level fill level sensor, overfill
level fill level sensor).
Check the following possibilities:
•
Working level fill level sensor
(
Fig.9.1.4.1.B
) soiled?
Clean with suitable cloth if necessary.
•
Work level fill level sensor
(
Fig.9.1.4.1.B
) damaged (scratches,
cracks)?
•
Switch off cleaning machine and
restart: Contact Service if the fault
persists.
205
Abortion
Both fans are defective
or blocked!
Program has not been
ended.
Failure of both fans.
Check the following possibilities:
•
Check fans for foreign bodies and
remove if necessary
•
Switch off cleaning machine and
restart: Contact Service if the fault
persists.