Putting unit into operation
18
BA_ Elmasonic xtra ST 1900S_EN_Vers.04.2019
© Elma Schmidbauer GmbH
6.2
Heating up of the cleaning liquid
Heat up the cleaning liquid depending on the kind and degree
of contamination of the cleaning items to assist the cleaning
effect. To keep the heating period as short as possible we
recommend to use the cover.
You may also switch on the ultrasound to further speed up the
heating process.
The ultrasonic energy is transformed physically into heat.
Therefore, low preset temperatures may be exceeded during
ultrasonic operation.
In order to avoid unintended heating over the required
temperature due to the additional ultrasonic energy, set the
temperature at the lowest possible value for the cleaning task at
hand.
High temperatures! Risk of burning and scalding!
Cleaning liquid, ultrasonic tank, housing, cover, basket and
cleaning items may heat up considerably depending on the
temperature inside the bath.
Do not reach inside the bath!
Wear protective gloves to handle the unit and basket!
1. Press the key
on/off
(
Fig. 4.11.A
), the green LED in the key
is lighted.
2. Press the key
heating
(
Fig. 4.11.B
), the green LED in the
key is lighted.
3. Set the required cleaning temperature by pressing the
+/- keys (
Fig. 4.11.C)
, the LED indicating the set
temperature is lighted. The heating process is started and
the actual temperature is indicated by the flashing LED (
Fig.
4.11.D
).
4. As soon as the set temperature is reached the heating
automatically switches off.
The ultrasonic energy can heat up the cleaning liquid over the
set temperature. Particularly low set temperatures (e.g. 30°C or
40°C) can easily be exceeded.
CAUTION
How to proceed