Trouble shooting / List of malfunctions
© Elma GmbH & Co KG
SM/Transsonic_LC/1104/D
17
6.4
T780 – T1060H
Malfunction
1. Check:
Pilot
lamp
ultra-
sound
2. Check:
Heating
switch
- if
lighted
3. Check:
Fuse
inter-
ference
filter
4. Check:
Fuse
printed
board
Possible
causes
Remedy
Check the unit for possible damages and traces of liquid inside (e.g. leak in the
tank, liquid/humidity entering from outside)
No ultrasound
/ weak
ultrasound
(Heating OK)
OK
OK
OK
OK
•
secondary
transformer
coil
•
output
capacitor
•
scorching in
transducer
system
•
replace
component
•
replace
compl.
printed
board
•
open/
check
transd.
system
No ultrasound
(Heating OK)
OK
OK
OK
faulty
•
printed
board:
(transistors
diodes)
•
replace
component
•
replace
compl.
printed
board
No ultrasound
(Heating OK)
OFF
OK
OK
OK
•
interference
filter
•
timer
•
replace
component
•
replace
compl.
interf. filter
No ultrasound
No heating
OFF
OFF
OK
OK
•
interference
filter
•
mains cable
•
replace
component
•
replace
compl.
interf. filter
•
replace
mains
cable
Summary of Contents for LC130H