4.4 I-TIME
The integration time (I-time) can be set between 0 and 2000 seconds.
The set time starts when the measured value exceeds one of limit 3 or 4 (only when proportional
regulation is chosen). After expired I-time the frequency is doubled (at frequency regulation) or the on-
time is doubled (at PWM-regulation) compared with P-regulation. The doubling is performed with an
interval corresponding to the set I-time until either the measured value is within the limits or that max
frequency (alt. max on-time ) is reached. The regulation is then performed with max frequency (alt.
max on-time) until the measured value is within the limits.
In the example below the P-band is 80% (80 % -units), max frequency 180 Hz, I-time 600 seconds
and frequency regulation chosen as regulation form. The limit value is 20%.
20
40
60
80
100
120
140
160
180
frequency(Hz)
time (sec)
0
0
600
1200
1800
%
P-Band
20
40
60
80
100
T
h
e
in
fl
ue
nc
e
o
f
I-
ti
m
e
P-
re
gu
la
tio
n