V1.0: If no error is present, then LED Power shows the function control (briefly off).
V2.1 and later: If no error is present, then LED Power shows the operating state (on).
During the output of an error message, the number of output pulses indicates the error:
Pulse Error message
1
Voltage supply outside of the valid value range
2
ELMON inductive transmission error
3
Output control Open faulty
4
Output control Close faulty
5
Data transmission between microcontrollers faulty
6
Testing sensor input faulty ( stationary contact edges) (Open/Close)
6
.3 Connection terminals
STOP Opening
Control circuit (emergency-off)
Stop, direction of movement - Opening (channel 1)
STOP Closing
Control circuit (emergency-off)
Stop, direction of movement - Closing (channel 2)
STATIONARY Opening Sensor input
Direction of movement - Opening (channel 1)
STATIONARY Closing
Sensor input
Direction of movement - Closing (channel 2)
Transmit
No assignment
24 V AC/DC
Supply voltage 24 V AC/DC
L1 N
Supply voltage 230 V 50/60 Hz
7. Mechanical mounting
The switching unit is to be professionally mounted at a suitable location. After removing the cover, the housing
can be mounted with four screws.
Do not install the switching unit in the immediate vicinity of strong sources of heat.
The switching unit may be mounted in any orientation. To prevent moisture penetration, it should, however,
be installed so that the cable conduits point downward.
ELMON relay 32-312
Safety Relay