11
A=B
NEEDLE DROP POSITION ALIGNMENT
NEEDLE DROP POSITION ALIGNMENT
NEEDLE DROP POSITION ALIGNMENT
NEEDLE DROP POSITION ALIGNMENT
NEEDLE DROP POSITION ALIGNMENT
SELECT THE STITCH PATTERN " "; THE STANDARD NEEDLE DROP
SELECT THE STITCH PATTERN " "; THE STANDARD NEEDLE DROP
SELECT THE STITCH PATTERN " "; THE STANDARD NEEDLE DROP
SELECT THE STITCH PATTERN " "; THE STANDARD NEEDLE DROP
SELECT THE STITCH PATTERN " "; THE STANDARD NEEDLE DROP
POSITION SHOULD BE AT THE CENTER OF THE NEEDLE PLATE HOLE.
POSITION SHOULD BE AT THE CENTER OF THE NEEDLE PLATE HOLE.
POSITION SHOULD BE AT THE CENTER OF THE NEEDLE PLATE HOLE.
POSITION SHOULD BE AT THE CENTER OF THE NEEDLE PLATE HOLE.
POSITION SHOULD BE AT THE CENTER OF THE NEEDLE PLATE HOLE.
WHEN THE NEEDLE SWINGS IN MAXIMUM ZIGZAG WIDTH " ", THE
WHEN THE NEEDLE SWINGS IN MAXIMUM ZIGZAG WIDTH " ", THE
WHEN THE NEEDLE SWINGS IN MAXIMUM ZIGZAG WIDTH " ", THE
WHEN THE NEEDLE SWINGS IN MAXIMUM ZIGZAG WIDTH " ", THE
WHEN THE NEEDLE SWINGS IN MAXIMUM ZIGZAG WIDTH " ", THE
CLEARANCE BETWEEN BOTH ENDS OF THE NEEDLE HOLE IN THE NEEDLE
CLEARANCE BETWEEN BOTH ENDS OF THE NEEDLE HOLE IN THE NEEDLE
CLEARANCE BETWEEN BOTH ENDS OF THE NEEDLE HOLE IN THE NEEDLE
CLEARANCE BETWEEN BOTH ENDS OF THE NEEDLE HOLE IN THE NEEDLE
CLEARANCE BETWEEN BOTH ENDS OF THE NEEDLE HOLE IN THE NEEDLE
PLATE AND THE NEEDLE SHOULD BE 0.2 MM OR MORE. IF NOT, ADJUST AS
PLATE AND THE NEEDLE SHOULD BE 0.2 MM OR MORE. IF NOT, ADJUST AS
PLATE AND THE NEEDLE SHOULD BE 0.2 MM OR MORE. IF NOT, ADJUST AS
PLATE AND THE NEEDLE SHOULD BE 0.2 MM OR MORE. IF NOT, ADJUST AS
PLATE AND THE NEEDLE SHOULD BE 0.2 MM OR MORE. IF NOT, ADJUST AS
FOLLOWS.
FOLLOWS.
FOLLOWS.
FOLLOWS.
FOLLOWS.
ADJUSTMENT PROCEDURE:
ADJUSTMENT PROCEDURE:
ADJUSTMENT PROCEDURE:
ADJUSTMENT PROCEDURE:
ADJUSTMENT PROCEDURE:
1.
TURN ON THE POWER SWITCH, SELECT THE STRAIGHT STITCH PATTERN " " AND THE ZIGZAG
WIDTH AT MAXIMUM " " THEN CHECK THE NEEDLE DROP POSITION.
2.
IF THE NEEDLE DROP POSITION IS NOT IN THE CENTER OF THE NEEDLE PLATE HOLE WHEN THE
STRAIGHT STITCH IS SELECTED, OR IF THE CLEARANCE BETWEEN THE NEEDLE AND EDGE OF
THE NEEDLE PLATE HOLE ON BOTH SIDE IS LESS THAN 0.2 MM WHEN THE STITCH PATTERN IS
SET TO MAXIMUM ZIGZAG WIDTH, REMOVE THE FACE COVER AND LOOSEN THE SETSCREW, THEN
ADJUST THE NEEDLE DROP POSITION BY TURNING THE ECCENTRIC PIN.
N O T E :
N O T E :
N O T E :
N O T E :
N O T E :
MAKE SURE THE ECCENTRIC PIN IS POSITIONED WITH ITS OFF-CENTER HEAD FACING DOWNWARD.
WHEN YOU HAVE FINISHED ADJUSTING THE NEEDLE DROP POSITION, TIGHTEN THE SETSCREW
AND ATTACH THE FACE COVER.
ECCENTRIC PIN
SETSCREW 3 X 4
NEEDLE PLATE HOLE
0.2 MM OR
MORE
0.2 MM OR
MORE
ECCENTRIC PIN POSITION
(OFF CENTER HEAD)
ADJUST THE NEEDLE DROP POSITION BY TURNING THE
ECCENTRIC PIN AS SHOWN
Summary of Contents for 6200 -
Page 1: ......