4/7
901A0004A01M - V03 Date:
28.06.2019
Ultrasonic sensor 2UF
en
5.1
Type code
Pos.
Exam
-
ple
Meaning
1
2
Reference
●
2 = Base number ultrasonic sensor
2
U
Measuring method
●
U = Ultrasound
3
F
Housing / flange
●
F = Vehicle housing
4
1
Material / flange /
thread
●
1 = PA
5
0610
Installation length
in mm
●
Typical: 610 mm
6
1
Output signal
●
0 = Voltage output 1-5 V
●
1 = Current output 4-20 mA
●
2 = Current output 0-20 mA
●
3 = Voltage output 0-5 V
●
4 = Voltage output 0-10 V
●
7 = Voltage output 0-5-4.5 V
●
... = TBD other signal outputs
7
0
Display
●
0 = No display
8
1
Focus tube
●
0 = No focus tube
●
1 = With focus tube, material PA
●
... = other materials, TBD
9
B
Seal
●
A = Flat seal, material NBR
●
B = Flat seal, material FKM
●
C = O-Ring, material NBR
●
D = O-Ring, material FKM
●
... = other seals, TBD
10
A
Connection
●
A = AMP 3 pole
11
01
Sequence number
●
00 = Output signal averaged over 20s
●
01 = Output signal averaged over 1s
●
xx = Sequential from 02
For further details see the supplied datasheet.