background image

Art.-Nr./Art. No./Réf./N° art.: 9010007B01M

Version

: 1.2

Date

: 21.03.2017 

   

4/6

Safety-related characteristic 
data

1)

eloFlex 

470EFR2D...

eloFlex 

470EFR3E...

SIL acc. to IEC/DIN EN 61508

2

3

SIL

CL

 acc. to IEC/DIN EN 62061

2

3

PL according to
DIN EN ISO 13849-1

d

e

Category according to 
DIN EN ISO 13849-1

3

4

PFH

D  

2)

7,42 x10

-8 

1/h

6,23 x10

-8 

1/h

Service life in years

20 

Hardware fault tolerance (HFT)

1

Class

B

Operating time of sensor contacts 
Actuation (typical)

3 s

Operating time of 2-hand control

0,5 s

Max. response time

50 ms

1)

Additional safety-related

characteristics upon request.

2)

Assumptions for calculation in

accordance with IEC TR 62380:
daily cooling to 20°C followed by
continuous operation at 55°C and
max. 10 switching cycles per hour

Terminal connections

eloFlex 

470EFR2D...

eloFlex 

470EFR3E...

Operating voltage

1, 13

Sensor supply voltage (+)

5, 9

Sensor supply voltage (-)

7, 11

Safety input 1

6, 8

Safety input 2

10, 12

Safety output 1

4, 16

Safety output 2

3, 15

External contactor/start

2

Control output 1

14

Summary of Contents for 470 EFR 2D1 2K

Page 1: ...e use of the safety control unit does not exclude risks to persons or damage to machine or system components Please also observe the relevant information stipulated in the ISO 14119 standards Ensure that no current or voltage peaks which are higher than the specified electrical data of the safety control unit are caused by external components Current or voltage peaks may for example be generated t...

Page 2: ...oring Operating voltage 1 13 Control output 14 Not suitable for safety functions Switching dependent on Safety input 1 2 Logic Switch on switch off delay optional 1 3 5 4 6 2 LED 1 Operability Ready LED 2 Fault Error LED 3 Safety input 1 I 1 LED 4 Safety input 2 I 2 LED 5 Safety output 1 O 1 LED 6 Safety output 2 O 2 10 Commissioning In arbitrary order Damp safety sensors Apply operating voltage m...

Page 3: ...rt and storage temperature 40 85 C 40 85 C Electrical properties eloFlex 470EFR2D eloFlex 470EFR3E Operating voltage fuse fast acting 1 A Safety output fuse 3 A Operating voltage 24 V DC 10 Max current consumption 200 mA Status display 6 x LED Max switching voltage of safety outputs 1 2 250 V AC 30 V DC Max switching current of safety outputs 1 2 3 A Max switching capacity of safety outputs 1 2 75...

Page 4: ...rating time of sensor contacts Actuation typical 3 s Operating time of 2 hand control 0 5 s Max response time 50 ms 1 Additional safety related characteristics upon request 2 Assumptions for calculation in accordance with IEC TR 62380 daily cooling to 20 C followed by continuous operation at 55 C and max 10 switching cycles per hour Terminal connections eloFlex 470EFR2D eloFlex 470EFR3E Operating ...

Page 5: ...Art Nr Art No Réf N art 9010007B01M Version 1 2 Date 21 03 2017 5 6 Mechanical design 100 120 22 5 Schematic diagram Attention Example of circuit ...

Page 6: ... für Sensoren mit Schließer Schließer oder Schließer Öffner Kontaktsystem configurable safety related system for sensors with 2 normally open or normally open normally closed contact system elobau Artikel Nr elobau item no 470 EFR 2D1 2K 470 EFR 3E1 2K 470 EFR 3E1 1K Einschlägige EG Richtlinien Relevant EC Directives Maschinenrichtlinie 2006 42 EG EMV Richtlinie 2014 30 EU Machinery Directive 2006...