eloProg - Vers. 1.0
57
Î
WARNING: If the Enabled Reset is active, a consecutive Input has to be used. Example:
Input 1 and Input 2 are used for the functional block, then Input 3 has to be used for the
Reset Input.
Output test
: This is used to select which test output signals are to be sent to the component
contacts. This additional test makes it possible to detect and manage any short-circuits between
the lines. There is a choice of 4 possible test output signals, Test Output 1 ÷ Test Output 4.
Test at start-up
: If selected this enables the test at start-up of the external component. This test is
performed by opening the mobile guard or safety gate to run a complete function test and enable
the output. This test is only requested at machine start-up (when the unit is switched on).
Filter (ms)
: This is used to filter the signals coming from the external contacts. The filter can be
configured to between 3 and 250 ms and eliminates any bouncing on the contacts. The length of
the filter affects the calculation of the unit's total response time.
Concurrent enable
: If selected this activates the test to verify concurrent switching of the signals
coming from the external contacts.
Concurrent (ms)
: This is only active if the previous parameter is enabled. It defines the maximum
time (in msecs) between the switching of two different signals from the external contacts.
Object description
: This allows a description of the component's function to be entered. The text is
displayed in the top part of the symbol.