background image

 

Photoelectric Beam Detector 

EL-PB60 S 

 

 

Features 

EL-PB60S   Photoelectric Beam Detector ( 60M ) 

ƒ

  Wide angle adjustment   

ƒ

  External light protection  

ƒ

  Protection against frost/dew, Guaranteed quality of front cover  

ƒ

  High convenience for installation and wiring  

ƒ

  Safety Approval: CE  

Specification 

ƒ

  Protection range: Outdoor : 60m Indoor : 120m  

ƒ

  Detection method:  Simultaneous breaking of 2 beams 

ƒ

  Infrared beam:  Double modulation pulsed beams by LED 

ƒ

  Response time:  50 ~ 700mS 

ƒ

  Supply voltage:  DC 10.8 ~ 25VDC(Non-polarity) 

ƒ

  Current:  Max. 57mA 

ƒ

  LED:  Tx : Power(Green LED),  

Rx :Sensitivity good (Green LED),   
When an alarm is initiated (Red LED) 

ƒ

  Alarm output:  Dry contact relay output form C,  

Contact action : Interruption time  +delay time(1~3 sec),  
Contact capacity : 30V(AC/DC) 1A or Less 

ƒ

  Tamper output:  Dry contact relay output form N.C(Rx only),  

Contact action :  Activated when cover is detached,  
Contact capacity : 30V  (AC/DC) 1A or Less 

ƒ

  Temperature:  -20

Ԩ

 ~ 60

Ԩ

 

ƒ

  Beam Adjustment:  Horizontal : 180˚(±90˚), Vertical : 20˚(±10˚) 

ƒ

  Mounting site:  Indoor/Outdoor 

ƒ

  Material:  Cover : PC resin, Base : ABS resin 

ƒ

  Dimension:  63 x 163 x 75mm (W x H x D) 

ƒ

  Weight:  Rx : 330g, Tx : 315g 

ƒ

  Function:  Monitor jack output, Frost proof cover 

ƒ

  IP rating:  IP 44 

 

 

EL-PB60S

 

Summary of Contents for EL-PB60S

Page 1: ...25VDC Non polarity Current Max 57mA LED Tx Power Green LED Rx Sensitivity good Green LED When an alarm is initiated Red LED Alarm output Dry contact relay output form C Contact action Interruption time delay time 1 3 sec Contact capacity 30V AC DC 1A or Less Tamper output Dry contact relay output form N C Rx only Contact action Activated when cover is detached Contact capacity 30V AC DC 1A or Less...

Page 2: ...e visibility ran ace fog occ lation m Detec nstructio ur photoelec installed P gned to dete sponsible fo by lightening tector is dam tector may b r or replace ge or possi ur frequent ctor on ctric beam d Please read ect intrusion or damage g abuse m maged if it i be damaged e any parts ble distance ly detector Th this Instruc n and to init injury or los misuse abn s connected d if the app e can se...

Page 3: ...P 2 3 4 Photoe Part Des Respons Expansio electric cription se Time on of Beam c Beam m and Posit m Detec tion of Inst ctor tallation E EL PB60 S ...

Page 4: ...ic Beam Detector EL PB60 S 5 Installation 6 Channel Setting This function is used for purpose of preventing cross talk or bypass of beams which may occur in line protection or 2 stacked protection Set beam channel ...

Page 5: ...m Detec k with volt m r detached recover lens r on both si Using the a g the unit to r on the view horizontally and verticall ctor meter digita s by the vie ide and line adjuster the work in all w finder of i y and vertic ly to get hig l to confirm w finder e up optics h e lens can m the directio nside middl cally to get h ghest voltag m optical alig horizontally move horizo ons The op le mirror h...

Page 6: ... as power machine is located nearby Tx and Rx Change the place for installation Unstable installation of Tx and Rx Stabilize Solied optics of Tx and Rx Clean the optics with a soft cloth Improper alignment Check and adjust again Small animals may pass through the 2 beams Set the response time longer 10 Dimensions Limited Warranty elock Products are warranted to be free from detect in material and ...