background image

PS710 | INSTRUCTIONS FOR USE

 3

        

IMPORTANT! read this section before using the  

 

 

  PS710!

1. Personal safety

Personal injury risk

- This equipment may only be used by persons with sufficient knowledge  
   about it’s application and function.
- Before the Product is used this Instruction for use must be studied care-   
  fully and all instructions must be followed.
- The use of other hydraulic tools than from Elpress may bring about con-
                          siderable risks for personal injury.

PS710 is an electro hydraulic pump exclusively designed for the use of Elpress hydraulic tools.
The mains cable may only be connected to a 100-240 VAC outlet with protective earth (PE).
This Instruction for use shall always be kept with the PS710.

-  The PS710 creates a very high working oil pressure (up to 700 bar or 10 000 psi) in
  the pump, hose and tool. To minimize the risk when handling, always use
  protective glasses and gloves.
-  Do not try to disconnect tool in pressurised state.
                          -   The control handle has to be connected to the tool.

Always check the PS710 before use, with special regards to damage on the hose, control cable, 
attached tool and mains cable. If damage is seen or suspected, the unit must not be used and 
immediate service actions must be taken.
Note that only authorised service units with access to technical documentation may service the 

PS710. Always use spare parts supplied from Elpress. 

Note that the hose for this unit may look much like any hydraulic hose, but carries about three 
times the pressure of conventional hydraulic hoses. It is therefore absolutely necessary to use only 
hoses and fittings designed for these high pressures.
Reduce the safety risks and prolong the service time for the PS710 by handling it with care and by 
keeping it clean.
Do not work with attached tools directed towards any one.

Observe the movements of the attached tool to avoid finger damages.
An attached tool is quickly “freezed” by releasing the start switch on the control handle. 
The stop switch stops and retracts the tool movement. This function is checked at each 
starting up sequence.

At longer stops, switch off the unit and disconnect the mains cord plug.

The

 PS710

 must not be used for work in explosive environments.

Summary of Contents for 7393487047655

Page 1: ...PS710R PS710E PS710D PS710 INSTRUCTIONS FOR USE GB...

Page 2: ...L SAFETY 3 2 ASSISTANCE 4 3 GENERAL DESCRIPTION 4 4 PS710 SYSTEM COMPONENTS 5 6 5 FUNCTIONS 7 6 DISPLAY MENU 8 7 USE OF THE PS710 8 9 8 MAINTENANCE 9 10 9 DISPOSAL 10 10 TECHNICAL SPECIFICATION 11 11...

Page 3: ...s check the PS710 before use with special regards to damage on the hose control cable attached tool and mains cable If damage is seen or suspected the unit must not be used and immediate service actio...

Page 4: ...zing possibility PS710D is the version for cable harness manufacturing with high flow pump CAN bus for com munication with Elpress CS2500 crimp unit and PC software for crimp process control and analy...

Page 5: ...ry Power connection PC Software for crimp analysis and quality process integration 1 Start 2 Stop 3 Battery cover AAA 1 5 2 st 2 mm allen key Battery status of the control handle is indicated by 2 5V...

Page 6: ...on Crimp station CS2500 Foot pedal Pump PS710D Hydraulic hose Hydraulic connection Handle connection Carrying handle Main switch Power connection PS710R Back PS710R Front 4 PS710 System components PS7...

Page 7: ...y never run the pump without tool crimping or cutting tool 1 Set main switch in position off 2 Connect the mains cord plug to a 100 240 VAC power outlet with protective earth PE 3 Set main switch in p...

Page 8: ...eristic Cycle counter Counts every crimp p 15 bar possible to reset Total counter A not resetable total press counter Press time Crimp time when pressure p is over 15 bar Max pressure Max hydraulic pr...

Page 9: ...ectors and mains cable is important If damages occur these components must be replaced before using the pump as it affect personal safety When hydraulic hose and cable are disconnected from the pump t...

Page 10: ...s issued after the equipment has complied with calibration requirements Elpress service agreements are arranged per tool and service level Elpress Basic Preventive maintenance calibration with certifi...

Page 11: ...l volume 1 0 litre Oil type HYDREX MV 22 hydraulic oil mineral type or similar Mains power 85 276 VAC 50 60 Hz Dimensions 370x170x280 Weight 11 5 kg Battery PS710E Li ion 28 8 V 3 0 Ah Crimps battery...

Page 12: ...PS710 INSTRUCTIONS FOR USE 12 11 Declaration of conformity...

Page 13: ...PS710 INSTRUCTIONS FOR USE 13 11 Declaration of conformity...

Page 14: ...ld model 5260 010100 5220 070300 Battery PS710EBP Quantity 8010 051400 1 2 Battery charger PS710EBC For EU 8010 051500 For USA compl with converter 8010 058300 Analyzer 5220 189400 Strap 8021 001200 F...

Page 15: ...BC US compl 8010 058300 Strap 8021 001200 PS710ECN 5204 009500 PS710E 5204 009100 Mains cable China 8010 051300 PS710EBP 8010 051400 PS710EBC CN US 8010 052300 Strap 8021 001200 PS710RCN 5204 009600 P...

Page 16: ...8052 060500 Elpress AB P O Box 186 SE 872 24 KRAMFORS SWEDEN Tel 46 0 612 71 71 00 Fax 0 46 612 71 71 51 E mail sales elpress se www elpress net...

Reviews: