Page 11
4
、
Adjust the layouts of pickups and speakers to reduce the occurrence of whistling.
3
.Connections to PTZ
A.
The PTZ decoder must share a common ground with the DVR or possible presence of
common-mode voltage may cause you to lose control of the PTZ.
We recommend shielded twisted pair cable with its overall shield being used for common
ground;
B. Prevent against high-voltage power surge. Wire cables must be able to protect equipment from
lightning
C.
Connect a 120 Ohm resistor in parallel at the far-end to reduce reflection and guarantee the
signal quality;
D.
The AB-wire connectio
ns of the DVR’s 485 cable cannot be combined with 485 cables from
other output devices;
E.
AB line voltage of the decoder should be lower than 5V.
4. Ground Wires of front-end equipment
Incorrect grounding may result in chips being burned.