Menu 6.4 – Service Call
This sets the number of complete cycles (open and close) required before the built-in buzzer is
activated. Also the control card outputs can be configured to be activated if the number of cycles is
completed. Connecting Elsema’s GSM receiver to the output allows owners to get a phone call & SMS
message when the service is due.
When “Service Call Due” message shows up on the LCD a service call is required. After service has
been done, follow the messages on the LCD.
Menu No.
Service Call Mode
Factory
Default
Adjustable
6.4.1
Service Counter
Off
Min: 2000 to Max: 50,000
6.4.2
Exit
Menu 6.5 – Locking Actuator
The time for which relay output 1 turns “on” before the gate starts to open and the time for which relay 2
turns “on” after the gate is fully closed can be adjusted as below:
Menu No.
Locking Actuator
Factory
Default
Adjustable
6.5.1
Pre-Open Lock Activation
Off
1 – 30 seconds
6.5.2
Post-Close Lock Activation
Off
1 – 30 seconds
6.5.3
Exit
6.5.1 Pre-Open Locking Actuator Activation
This sets the time relay 1 is activated before the gate operates in the open direction. Factory default is
Off.
6.5.2 Post-Close Locking Actuator Activation
This sets the time relay 2 is activated after the gate is fully closed. Factory default is Off.