ELSEMA
4G Receiver with relay output, G-2025
Page
12
www.elsema.com
When inputs 1 & 2 are triggered, it will stay in alarmed status for 1 minute and the siren output switches ON.
The Digital inputs 1 & 2 will only trigger an alarm in the following conditions:
1.
The GSM receiver is in armed mode
2.
10 minutes after the last call from an authorized user. Factory default is 10 minutes but this time can be
changed. (minimum is 1 minute)
3.
Digital Inputs 1 & 2 will re-arm after 30 seconds from a sensor input.
Changing the time after which Input 2 becomes active
o
PwdDtime#
Time: 000—999 in minutes. 000 means the GSM receiver will always be disarmed
E.g If the user wishes to change the time to 2 minutes after which input 2 becomes active, the following
SMS command is needed (minimum is 1 minute).
1234D002#
Power failure SMS
o
PwdACtime#
Time: 000—999 in minutes.
000 means the GSM receiver will send SMS message to the 1
st
user when the AC power fails.
999 means no SMS message will be sent when AC power fails.
Self-diagnostic SMS report to the 1
st
user
o
PwdT#time#
Time: 000—999 in hours.
000 means the GSM receiver will not send any message.
Self-diagnostic SMS will include the following:
Checking the Self-diagnostic SMS report time and status
o
PwdT#
Check current status
o
PwdEE
Arm / Disarm Status;
Digital Input 1 & 2 status;
Relay status;
Mobile signal strength (31 is strong signal, lower than 14 is weak signal)
AC power supply status