www.elsema.com

 

 

 

Delete a user  

o

 

PwdAserial number##

 

E.g A user on position 13 (serial number 13) has to be deleted from the user list, the following SMS 
command is needed: 
 

 

1234A013## 

It is recommended to keep a list of all users and their numbers position.

 

If a new number is programmed on a location which already has a number stored, the old number will be deleted 
and the new number is stored. 
 

 

Allow access to all numbers calling the GSM receiver 

o

 

PwdALL#

 

To allow access to anyone making a call to the GSM receiver, the following SMS command is needed: 

Warning! This will allow anyone who makes a call to operate the GSM receiver. 

 

 

1234ALL# 

 

 

 

 

Allow access only to authorized numbers calling the GSM receiver 

o

 

PwdAUT#

 

To allow access to authorized numbers only, the following SMS command is needed: 
 

 

1234AUT# 

This allows only the numbers that are authorized to operate the GSM receiver.  

*This is set as factory default and is recommended for secure operation.

 

 

 

Setup Relay OFF delay 

o

 

PwdGOTclose time#

 

The relay OFF delay can be set from 000-999 seconds. The factory default is 0.5 seconds. 
000—0.5 second  
999— Latching mode. Relay will stay ON until a second call is made.    
E.g. If the relay OFF delay needs to be set at 10 seconds, the following command is needed 

1234GOT010# 

Relay will stay ON for 10sec once activated.  
 

 

Controlling the relay with SMS messages 

o

 

PwdCC

 

 

 

1234CC 

 

Switches the relay ON (The relay stays ON for the OFF delay time set in the above command) 

o

 

PwdDD

 

 

 

1234DD 

 

Switches the relay OFF

 

Summary of Contents for G-2025

Page 1: ...h Optus All you need is to insert a valid SIM card and program phone numbers of all users using the PC software or through simple SMS text commands When an authorized user makes a call to the receiver...

Page 2: ...eless equipment might interfere with the 4G network signals of the G 2025 and influence its performance Avoid using at Petrol Gas Stations Do not use G 2025 at a petrol gas station Power off the GSM R...

Page 3: ...210xUSB to UART Bridge for example COM3 7 If this driver is not visible install the driver from the USB flash drive included 8 Run the configuration software type in the COM Port number for example CO...

Page 4: ...ttings from the GSM receiver to the PC software 2 Save Settings Save the basic parameter settings to the GSM receiver 3 Import profile Import xls profile All settings can be imported from the GSM rece...

Page 5: ...uthorized number list in xls format from the PC to the configuration software 4 Export xls Export the authorized number list in xls format to the PC under the configuration folder 5 Export csv Export...

Page 6: ...t the start and the end Date and Time of the data which you wish to view 3 Export xls Exports the historical data in xls format to the PC under the configuration folder 4 Export csv Exports the histor...

Page 7: ...GSM receiver try adding in front of the phone numbers or the country code SMS command structure SMS Commands Below are the SMS command needed for the GSM receiver In the examples the default password...

Page 8: ...mbers are mobile numbers of all users who will be using their phones to operate the GSM receiver Serial number is the position of all stored numbers authorized users 001 999 users It is strongly recom...

Page 9: ...receiver 1234ALL Allow access only to authorized numbers calling the GSM receiver o PwdAUT To allow access to authorized numbers only the following SMS command is needed 1234AUT This allows only the...

Page 10: ...low AB Option SMS Confirmation to user A First user B Caller 1st user Caller 0 0 0 1 1 0 1 1 0 means disable 1 means enable Content is the SMS message which the user and the caller will receive E g If...

Page 11: ...or inputs to be active the GSM Receiver should be armed either with SMS or the PC Software Change Digital input 1 from NO to NC Factory default is Normally Open NO o PwdDIN1NC E g To change Input 1 fr...

Page 12: ...iver will always be disarmed E g If the user wishes to change the time to 2 minutes after which input 2 becomes active the following SMS command is needed minimum is 1 minute 1234D002 Power failure SM...

Page 13: ...r ON Power ON indicator Alarm ON The LED lights up when the inputs are triggered and there is alarm condition Relay ON The LED lights up when the relay switches ON Network Signal Flash every 1 Second...

Page 14: ...ELSEMA 4G Receiver with relay output G 2025 Page 14 www elsema com Application GSM receiver 12 24 Volts DC application GSM receiver 240 Volts application...

Reviews: