background image

 

   Safety Precautions 

                     

                      

 

 

WARNING!

 

 FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION 

INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND

/

OR DAMAGE TO PROPERTY AND 

EQUIPMENT

  Appropriately licensed and competent personnel only should install the automation equipment. 

  The operators are designed specifically to open and close sliding gates or doors and should not be 

used for any other purpose. 

  Before commencing installation, read through this installation manual. 

  Check that the operator and controls are in new condition and have not been damaged in transit. 

 

Check the gate or door and it’s associated support posts and walls to protect against shearing, 
compression and other various traps which could cause serious injury or death. Take into 
consideration the general installation and surrounding environment. 

  Check the gateposts or mounting structure has the necessary strength and rigidity to support the 

operator and the load of the opening and closing gate motion.

 

 

          

          

      

CAUTION!

        

          

          

             

Always incorporate the appropriate Photo Electric Cells, Safety Bump Strip, Induction Loops 
and other safety devices to protect both equipment and personnel. 

Elsema Pty Ltd 

recommends a Photoelectric Beam to be installed and operational when any of the Auto Close 
options are used. 

 

  Display any necessary signs to indicate any danger areas and automatic operation of the gate or door. 

  The operators are not designed to be used in any hazardous areas or areas subject to flooding etc. 

  All electrical connections and wiring must be performed with AS/NZS 3000-2018 as the guidelines. (Or 

its counterpart for other countries outside of Australia and New Zealand)  

 

WARNING! ELECTRICITY CAN KILL 

 

  The manufacturer of the automation equipment is not responsible for the damage which may be 

caused to either the operator, gate or door and any other person or equipment when: - 

o

  Wrong or poor installation practices were performed. 

o

  No or inadequate safety devices were used. 

o

  Either the surrounding structure or the gate or door strength and rigidity was not sufficient for 

the task in hand. 

o

  Inefficient locking devices were employed. 

o

  Poor maintenance on the equipment. 

o

  Any other circumstances beyond the manufacturers control. 

 

Isolate power and battery before attempting any maintenance, qualified personnel only to carry out 
maintenance 

 

Only original spare parts are to be used should there be a requirement for them.  

 

Keep loose clothing and hands clear of the gate whilst in operation or potentially able to be operated.

 

 

The installer should provide all information concerning the use of the automation equipment as well as 
instructions regarding the manual override and maintenance procedures to the users of the system. 

Summary of Contents for INTELLIGENT SLIDER iS1500LV

Page 1: ...HIGH SPEED SLIDING GATE OPENER WITH BATTERY BACK UP Model iS1500LV Elsema s Eclipse Control Card USER MANUAL...

Page 2: ...tions are used Display any necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subject to...

Page 3: ...te base approximately 600mm long x 300 wide x 300mm deep should be laid where the gate operator is to be located IMPORTANT ensure there are gate stops firmly installed in the fully open and closed pos...

Page 4: ...een the rack teeth and Pinion wheel 3 Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs...

Page 5: ...g on them One should have a and the other should have a You cannot use the limit magnets if they have the same marking The magnets can be installed on either side open or close Please see the diagram...

Page 6: ...ening Photo Beam P E N C safety input Can be set for N O operation if needed through menu 3 1 PE beam operation modes can be changed through menu 4 2 Control Outputs 12VDC Supplies regulated 12VDC at...

Page 7: ...now be opened by hand To re engage the clutch move the gate by hand into approx the halfway position and turn the knob clockwise until it is very tight If when turning the knob clockwise and it just...

Page 8: ...r will not run inadvertently Gate rolls freely when in manual Gate wheels and guide rollers in good condition Gate stops are installed and in good condition not loose Gate rack is tight correct cleara...

Reviews: