Features 

 

Supply 12VDC 

 

Adjustable sensitivity (8 levels via dip switch) 

 

2 x Relay outputs (each can be configured individually) 

 

Power up and loop activation LED indicator. 

 

Industry standard 11-way plug-in type circular connector.  

 

Two loop detection function CH1 (10 way dip switch) and CH2  
(7 way dip switch). 

 

Application 

 

Controls automatic doors or gates when a vehicle is present source. 

 

Description 

Loop detectors in recent years have become a popular tool having innumerable applications in policing, right 
from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the 
loop detector.  
 
The digital technology of the loop detector enables the equipment to sense a change in the inductance of the 
loop as soon as it detects the metal object in its path. The inductive loop which detects the object is made of 
insulated electrical wire (32/020; 32 Strand, 2mm diameter) and is arranged either as a square or rectangle shape. 
 
The loop consists of several loops of wire and consideration should be giving to the loop sensitivity when 
installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum 
detection (8 levels via dip switch settings). Channel 1, is set by the 10 way dip switch and channel 2 is set by 7 
way dip switch. When detection occurs, the detector energises 2 relays for the output (each can be configured 
individually). This energising of the relay can be configured into different modes, by selecting the respective 
dipswitch. 

 

 
Technical Data  
  

Supply voltage 

12VDC 

Standby Current 

54 mA 

Operating Current 

73 mA 

Outputs 

2 changeover relays rated at 240VAC, 3A 

Connection 

Screw type terminal 

 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for MD12-2

Page 1: ...change in the inductance of the loop as soon as it detects the metal object in its path The inductive loop which detects the object is made of insulated electrical wire 32 020 32 Strand 2mm diameter...

Page 2: ...8 being the least sensitive and 0 015 being the most sensitive Dip switch 3 4 and 5 for CH2 sensitivity selection with 0 8 being the least sensitive and 0 015 being the most sensitive Dipswitch Setti...

Page 3: ...e used to solve the mistake operation recommended Dip switch Settings 3 of CH1 Function Special Functions Dip switch 3 is ON Direction Detection If vehicle is from CH1 to CH2 then CH1 relay should be...

Page 4: ...elay will give a pulse output for 600ms after a delay of 200ms Dip switch Settings 6 7 and 8 of CH1 Sensitivity Sensitivity Selection Eight Levels Choices Dip switch 6 7 and 8 is ON 0 015 highest sens...

Page 5: ...nel 2 Loop Function Selection 7 way dip switch Dip switch 1 of CH2 Function Relay Output Type Selection Dip switch 1 is OFF CH2 relay will be present output Dip switch 1 is ON CH2 relay output type is...

Page 6: ...Selection Dip switch 3 4 and 5 is ON 0 015 highest sensitivity range Dip switch 3 and 4 is ON 0 02 Dip switch 3 and 5 is ON 0 04 Dip switch 3 is ON 0 08 Dip switch 4 and 5 is ON 0 12 Dip switch 4 is O...

Page 7: ...tecting Led Continuously On Indicates vehicle detection Blinking slowly Indicates loop is short circuit or the number of twists after the loop is not enough Blinking fast Indicates loop is open circui...

Page 8: ...have been installed set one detector to high frequency and the other set to low frequency to minimize the effects of cross talk between the two systems The sensing loops and detectors should be positi...

Page 9: ...etectors Do not install the detector on vibrating objects When the control box is installed within 10 metres of the loop normal wires can be used to connect the control box to the loop More than 10 me...