MD12-2 Metal Loop Detector
- 3 -
Dip switch Settings
2 of CH2
Function
Automatic Reset (Both Channels)
Dip switch
2 is ON
Vehicle can be permanently present. (no auto-reset, unless vehicle
has left or manual reset)
Dip switch
2 is OFF
Normal mode, (automatic reset after 10minutes present of vehicle,
used to solve the mistake operation. recommended).
Dip switch Settings
3 of CH1
Function
Special Functions
Dip switch
3 is ON
Direction Detection. (If vehicle is from CH1 to CH2, then CH1
relay should be used; if vehicle is from CH2 to CH1, then CH2
relay should be used).
Dip switch
3 is OFF
Normal mode, Each loop activates respective relay.
Dip switch Settings
4 of CH1
Function
Special Functions
Dip switch
4 is OFF
CH1 relay will be present output
Dip switch
4 is ON
CH1 relay output type is pulse