4.3.6 Battery discharge time setting function (tod)
1. To enter the configuration interface, press and hold the configuration function key
for more than 2
seconds, then access the Configuration Interface. Press the key
until you reach the "tod" menu (6),
the word "tod" flashes:
2
Start the selection interface Battery discharge time setting: Press and hold the configuration function
key
for more than half a second (less than 2 seconds), enter the "tod" configuration interface, at
this point the write "Tod" will remain fixed. The numeric value under the word "tod" will blink. Press the
key
to select the desired option between 1m - 2m - 3m (default option) - 5m - 10m - 30m - 1h - 2h
- 3h - 4h - OFF (no time limitation).
3
Confirm the "tod" selection: After selecting the desired time, pressing the configuration function key
for more than half second (less than 2 seconds) confirms the selection. Now, the configuration of
the "tod" function is completed and the selection under "tod" will remain fixed.
4
Exit the Configuration Interface. Press and hold the configuration function key
for more than 2
seconds to exit and return to the main interface.
5
When the "tod" function is activated, the Ups (in battery operation) will turn off at the end of the
selected time by powering off the connected devices.
4.3.7 Auto battery test function setting (Abt)
1
Enter the setting interface. Press and hold the function setting key
for more than 2 seconds, then
come to setting interface, Press and hold the function setting key
and select the menu bPS (2), the
letters “bPS” will flash as following:
2
Enter the auto battery test setting interface. Press and hold the function setting key
for more than half
a second
(less than 2 seconds), then come to setting interface of ABT, at this time, the letters “ABT” will
light for a long time. The “ON” below the ABT will flash. Press and hold the inquiring key
for more than
half a second (less than 2 seconds) to determine whether the ABT function is used or not. If used, the
corresponding word is “ON”, if not, the word is “OFF”. It can be determined by yourself.