background image

NEMO2.0  

65 • 80 • 120 • 160 • 200 • 300 • 400 

LINE INTERACTIVE

 

Rev. 02  27 Gennaio 2017

 

 

  

–LCD DISPLAY 

 

 

 

1. 

Input Voltage 

2. 

Output Voltage 

3. 

Operation from Mains icon 

4. 

Operation from Battery icon 

5. 

Battery level 

6. 

Low battery 

7. 

Load level 

8. 

Overload 

9. 

Error icon 

 

– VISUAL/AUDIBLE SIGNALS 

 

Signals and Alarms on LCD display: 

 
 

1.  Mains ON - UPS OFF 

Situation that occurs when the UPS is connected to 
the mains but is not switched on. The LCD shows 
information but is not backlit. 
In this situation, the batteries are in charging mode. 

 

2.  Mains ON - UPS ON 

Situation  that  occurs  when  the  UPS  is  connected  to 
the  power  supply  and  is  switched  on  via  the  front 
panel  button.  After  the  end  of  the  beep  the  LCD  will 
turn  on  and  the  icon  "3"  will  appear  to  indicate  the 
operation of the power supply. The UPS is in normal 
mode,  the  load  is  protected  and  the  batteries  are 
being recharged. 

 
 

3.  Mains  OFF  -  UPS  ON  (Network  failure/  Battery 

Test) 

Situation that occurs when the UPS is switched on 
and there is an outage (or want to simulate it to 
perform the Battery Test). The icon "4" lights up to 
indicate battery operation. The batteries are now 
feeding the load and are discharging. A beep 
indicates the remaining autonomy, the more the 
beep

’s frequency is higher the less the autonomy 

time will be. When the battery reaches the end of discharge level, then  "6" icon will also start blinking.

Summary of Contents for NEMO 2.0 120

Page 1: ...NEMO2 0 65 80 120 160 200 300 400 LINE INTERACTIVE Rev 02 27 Gennaio 2017 1 Nemo2 0 65 80 120 160 200 300 400 Single phase Line Interactive series Uninterruptible Power Supplies USER MANUAL...

Page 2: ...s in order to avoid any overheating of the unit This equipment is intended to be used in interior Avoid installing the UPS in locations where water or excessive moisture are present Do not allow liqui...

Page 3: ...h cold start function which means that even if the power supply is unplugged the UPS can be activated simply by pushing the ON OFF switch and will operated supplied by the battery Autorestart Upon ret...

Page 4: ...on located on the UPS front panel and wait for the test completion until the beep ends and the blue display lights up Your UPS is now working From now on your computer and its connected devices are pr...

Page 5: ...300 400 LINE INTERACTIVE Rev 02 27 Gennaio 2017 5 5 LAYOUT AND DESCRIPTION UPS FRONT VIEW 1 2 Rear view Nemo2 0 65 80 Rear view Nemo2 0 120 3 4 5 6 3 5 4 6 Rear view Nemo2 0 160 Rear view Nemo2 0 200...

Page 6: ...r to the power outlet A fuse in the housing protects against overload 4 Output outlets Connect your loads to these outlets to be protected by the UPS 5 USB Communication ports For remote communication...

Page 7: ...nnected to the power supply and is switched on via the front panel button After the end of the beep the LCD will turn on and the icon 3 will appear to indicate the operation of the power supply The UP...

Page 8: ...display shows the icon 9 as in the figure moreover you will hear a continuous beep To reset the beep turn off the UPS with the On Off button on the front panel 8 TROUBLESHOOTING STATUS CAUSE SOLUTION...

Page 9: ...600W 800W 1000W 1500W 2000W Switching time 2 6 mS tpc IEC outlet 2 2 4 2 2 2 2 Schuko outlet 2 2 2 2 NOISE FILTERING Modem T port 10BaseT 100baseT RJ11 RJ45 network compatible BATTERY Typ Autonomy tim...

Page 10: ...cluded by the warranty Periodic maintenance and repair or replacement of parts subject to normal wear and tear Any modification or modification to the product without prior written permission from ELS...

Page 11: ...FETY INSTRUCTIONS pag 2 2 PRODUCT INTRODUCTION pag 3 3 INSTALLATION AND OPERATION INSTRUCTIONS pag 4 4 UPS TEST pag 4 5 LAYOUT AND DESCRIPTION pag 5 6 LCD DISPLAY pag 7 7 VISIBLE AUDIBLE SIGNALS pag 7...

Reviews: