51
Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Press the button to set the ventilation levels of the motorised roof ventilators for the
night-time re-cooling. The button is only activated once a night-time re-cooling period
has been set.
Use the arrow buttons to change the level according to your desire. Default setting:
Level 3.
Confirm your setting with the
OK
button.
Press the button to set the timed ventilation. Press Select to select the time during
which ventilation will occur. However supply air flaps are only opened if the set out-
door temperature is hit.
Activate one or more periods on the list. Confirm your setting by pressing
OK
.
To change any of the time periods, press
Timer
.
Set timer, page 59
Press the button to set the ventilation levels of the motorised roof ventilators for the
timed ventilation. The button is only active if a ventilation time has been set.
Use the arrow buttons to change the level according to your desire. Default setting:
Level 3.
Confirm your setting with the
OK
button.
Press the button to set the outdoor temperature above which the supply air unit should
remain closed (winter operation). Use the arrow buttons to change the value according
to your wish. Default setting: 1.0 °C.
Confirm your setting with the
OK
button.
Press the button to set the recirculating air function for heat recovery. Recirculation al-
lows heated air from the first area to be distributed in the entire room and so be used
for warming if required. In principle, the recirculation function only starts if the temper-
ature at the ventilator is at least 3° warmer than the indoor temperature.
NTC Exhaust Level
Only for exhaust air units.
Timed Ventilation
For all ventilation units.
Ventilation Level
Only for supply air units.
Outdoor Temp
Only for WFL
and ventilation units at MF output/RF Relay.
Heat Recovery
Only for roof ventilators WL610 and WL305.