84
Installation
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Structure of the connector board WS1000 Color
1
Multifunctional output 1
(potential-free)
2
Multifunctional output 2 (pot.-free)
3
Multifunctional output 3 (pot.-free)
4
Multifunctional output 4 (pot.-free)
5
Outer conductor L1
6
Outer conductor L1
7
Drive group 1
8
Drive group 2
9
Drive group 3
10 Drive group 4
11 Drive group 5
12 Drive group 6
13 Drive group 7
14 Drive group 8
15 Drive group 9
16 Drive group 10
17 Mains connection L/N/PE 230 V/50 Hz
18 Wall button 1 (terminals 1-3)
Wall button 2 (terminals 4-6)
Wall button 3 (terminals 7-9)
Wall button 4 (terminals 10-12)
19 Wall button 5 (terminals 1-3)
Wall button 6 (terminals 4-6)
Wall button 7 (terminals 7-9)
Wall button 8 (terminals 10-12),
20 Wall button 9 (terminals 1-3)
Wall button 10 (terminals 4-6),
21* Multifunctional input 1 (terminals 1-3)
Multifunctional input 2 (terminals 4-6)
22 Weather station (terminals 1-2)
23* Multifunctional input 3 (terminals 3-5)
Multifunctional input 4 (terminals 6-8)
24 Connector for flat-ribbon cable to front
board
25 Microfuse T6.3 A (Drive 1-5)
26 Microfuse T6.3 A (Drive 6-10)
27 Microfuse T630 mA
28 Slot KNX interface
*
Supply voltage indoor sensor (or e. g.
cameras) possible via MF inputs
(No. 21, terminals 1(+), 2(-) | 4(+), 5(-)
and No. 23, term. 3(+), 4(-) | 6(+), 7(-)),
max. 400 mA altogether.
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
21
22
23
24
25
26
27
28
Summary of Contents for 60121