Power Supply Systems KNX PS640+ and KNX PS640+USB

2

Power Supply Systems KNX PS640+ and KNX PS640+USB

 • Version: 19.08.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

2.3. Power Supply

2.3.1. Housing example with central operating unit

3.

Settings of the device

3.1. Starting Position

The following may be read off and set on the display of the power supply system
KNX PS640+:
• Reset of a line
• Recall of the data memory with operating hours, overcharge, external 

electrical surge, internal electrical surge, short circuit and excess temperature

• Recall of the operating data bus voltage, bus current and temperature
• Language of display
The display is dimmed after 60 seconds if during this period no key is pressed.

3.2. Key functions in display menu

3.3. Line reset

With key

 

, you return to the previous menu level.

3.4. Data memory

Move the cursor to the desired menu with the up and down keys and press key

 

.

3.4.1. Operating hours

3.4.2. Overload

3.4.3. External Overvoltage

3.4.4. Internal Overvoltage

3.4.5. Short Circuit

3.4.6. Excess Temperature

3.5. Operating data

The current values of
• Bus voltage
• Bus current
• Temperature on the circuit board of the device
are displayed.
With key

   

you return to the previous menu level.

3.6. Language

With key

   

you get back by one menu level to the basic setting.

4.

Disposal

After use, the device must be disposed of or recycled in accordance with the legal
regulations. Do not dispose of it with the household waste!

Confirms  the  selection,  moves  to  the  next
step.

One step back.

 

Changes a setting (selects a setting or changes 
a value). The cursor (the blinking rectangle) 
indicates the selected menu item.

ok

Confirms the settings and returns to the device 
main menu.

Yes

Reset is activated. The line is switched to neutral and 
shorted. The basic setting displays: „Reset is active!“

No

Reset not activated. The power supply system works in 
normal operation.

30 seconds

A reset of 30 seconds is started. Afterwards, the line is 
supplied with voltage as usual. During the reset state, 
which lasts 30 seconds, the basic setting displays: 
„Reset active: XX sec“ (countdown).

Fig. 4

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

In starting position, press key   once.

Line Reset 

>  ™

Data Memory

>

Operating Data >
Language

>

Press key   once more in order to get into
the sector 

Line reset

.

Reset: Yes             ™
          No
          30 seconds
Reset not active!

Move  the  cursor  (flashing  rectangle  at
right edge) to the desired setting with the
keys

   

or 

 

and confirm with key 

ok

.

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

In starting position, press key   once.

Line Reset 

>

Data Memory

>  ™

Operating Data >
Language

>

Move  the  cursor  (flashing  rectangle  at
right  edge)  to  the 

Data  memory

  menu

with the keys

   

and 

 

and confirm with

key  .

Hours ofOperation > ™
Overload         

>

Ext. Overvoltage  >
Int. Overvoltage  >

Short circuit    

>

Excess Temperat.  >

Run time:  0 years
  0 day  0 hrs.

< = Back

The operating hours of the power supply
system  are  displayed  in  years,  days  and
hours.
With  key

   

you  return  to  the  previous

menu level.

Run time:  0 years
  0 day  0 hrs.

< = Back

The number of overload incidents and the
total time in days, hours and minutes are
displayed.
With  key

   

you  return  to  the  previous

menu level.

External Overvoltage
was detected     
0 times.
< = Back

The  number  of  external  overvoltage inci

-

dents is displayed.
With  key

   

you  return  to  the  previous

menu level.

Internal Overvoltage
was detected     
0 times.
< = Back

The  number  of  internal  overvoltage  inci

-

dents is displayed.
With  key

   

you  return  to  the  previous

menu level.

A short at the bus was 
detected
 0 times.
< = Back

The  number  of  short  circuit  incidents  at
the bus is displayed.
With  key

   

you  return  to  the  previous

menu level.

Excess Temperature  on 
the board
was detected
 0 times!

The  number  of  excess  temperature  inci

-

dents on the circuit board of the device is
displayed.
With  key

   

you  return  to  the  previous

menu level.

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

In starting position, press key   once.

Line Reset 

>

Data Memory

>

Operating Data >  ™
Language

>

Move  the  cursor  (flashing  rectangle  at
right edge) to the „Operating Data“ menu
with the keys

   

and 

 

and confirm with

key  .

Bus Voltage    29.4 V
Bus Current    320 mA
Temperature   42.1°C

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

In starting position, press key   once.

Line Reset 

>

Data Memory

>

Operating Data >
Language

>  ™

Move  the  cursor  (flashing  rectangle  at
right edge) to the „Language“ menu with
the  keys

   

and 

 

and  confirm  with  the

key  .

Sprache

:Deutsch ™

Language :English
Idioma

:Espanol  

Taal 

:Hollands

Move  the  cursor  to the  desired  language
with the up and down keys and press the
key 

ok

.  The  display  automatically  jumps

to  the  previous  menu  in  the  desired  lan

-

guage.

Reviews: