29
1
Cable connection to the rain sensor in the housing cover
2
Connections for the drive mechanism (tension clamp, PE/N/up/down),
suitable for solid conductors up to 1.5 mm² or conductors with fine wires
3
Opening for the cable for the drive mechanism
4
Connections for voltage supply (230 V AC, tension clamp, L1/N/PE),
suitable for massive conductors of up to 1.5 mm² or conductors with fine
wires.
5
Opening for the cable for voltage supply
6 Microfuse
6.3
A
7
Programming LED. In normal operation, this LED indicates the receipt of a
valid data package by a short flashing
8
Programming key for the teaching in of the radio connection to the
operating unit
Connection of voltage supply and drive mechanism
The drive mechanism of the window is connected to the weather station. Several
drive mechanisms may be connected in parallel. In case of the parallel
connection of motors, please observe whether a group control relay is specified
by the motor manufacturer. Group control relays may be provided by Elsner
Elektronik or the motor manufacturer.
If motors are connected in parallel which are not suited for this
purpose, both motor and control system are damaged.
Motors with a rated input of more than 1000 Watt must be operated with a relay
or contactor with own feeder.
We offer appropriate power supply units for DC drive mechanisms. In case of
need, please indicate the type of motor, manufacturer and – if available –
technical data.
Pass the cable for voltage supply and drive mechanism through the rubber
sealing at the bottom side of the weather station and connect voltage (L1/N/PE)
and drive mechanism (PE/N/up/down) to the provided clamps.
Close the housing by putting the cover over the bottom part. The cover must
engage at the right and at the left with a clearly noticeable “click”.