6
Installation and start-up
Weather Station P04-KNX-GPS
• Status: 01.04.2020 • Errors excepted. Subject to technical changes.
Magnetic fields, transmitters and interference fields from electrical consumers (e.g. flu-
orescent lamps, neon signs, switch mode power supplies etc.) can block or interfere
with the reception of the GPS signal.
Fig. 1
There must be at least 60 cm clearance to oth-
er elements (structures, construction parts,
etc.) below, to the sides and in front of the de-
vice.
60 cm
Fig. 2
The device must be attached to a vertical wall
(or a pole).
Place the supply line in a loop before leading
it into the wall or junction box. This will allow
rain to drip off and not drain into the wall or
box.
Wall
or
pole
90°
Fig. 3
The device must be mounted in the horizontal
(transverse) direction.
Horizontal
Fig. 4
For installation in the northern hemisphere,
the device must be aligned to face south.
For installation in the southern hemisphere,
the device must be aligned to face north.
North
South