19
Transfer protocol
Weather Station Suntracer KNX sl basic
• Version: 11.03.2016 • Technical changes and errors excepted.
158
Brightness sensor 3 threshold value 1:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
159
Brightness sensor 3 threshold value 1:
Delay from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
160
Brightness sensor 3 threshold value 1:
Delay from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
161
Brightness sensor 3 threshold value 1:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
162
Brightness sensor 3 threshold value 1:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
164
Brightness sensor 3 threshold value 2:
Absolute value
Input/
Output
RWCT [9.4] DPT_Value_Lux
2 bytes
165
Brightness sensor 3 threshold value 2:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
166
Brightness sensor 3 threshold value 2:
Delay from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
167
Brightness sensor 3 threshold value 2:
Delay from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
168
Brightness sensor 3 threshold value 2:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
169
Brightness sensor 3 threshold value 2:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
171
Brightness sensor 3 threshold value 3:
Absolute value
Input/
Output
RWCT [9.4] DPT_Value_Lux
2 bytes
172
Brightness sensor 3 threshold value 3:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
173
Brightness sensor 3 threshold value 3:
Delay from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
174
Brightness sensor 3 threshold value 3:
Delay from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
175
Brightness sensor 3 threshold value 3:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
176
Brightness sensor 3 threshold value 3:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
178
Brightness sensor 3 threshold value 4:
Absolute value
Input/
Output
RWCT [9.4] DPT_Value_Lux
2 bytes
179
Brightness sensor 3 threshold value 4:
(1:+ | 0:-)
Input
-WC-
[1.1] DPT_Switch
1 bit
180
Brightness sensor 3 threshold value 4:
Delay from 0 to 1
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
181
Brightness sensor 3 threshold value 4:
Delay from 1 to 0
Input
-WC-
[7.5] DPT_TimePeriod-
Sec
2 bytes
182
Brightness sensor 3 threshold value 4:
Switching output
Output
R-CT
[1.1] DPT_Switch
1 bit
183
Brightness sensor 3 threshold value 4:
Switching output block
Input
-WC-
[1.1] DPT_Switch
1 bit
185
Total brightness threshold value 1:
Absolute value
Input/
Output
RWCT [9.4] DPT_Value_Lux
2 bytes
No.
Text
Function Flags
DPT type
Size