Brief Instruction

Mounting of WS1 Style-4 PF

Item number 60194

Warning, mains voltage! National legal regulations are to be 
observed. Installation, inspection, commissioning and 
troubleshooting of the device must only be carried out by a

competent electrician.

Preparing the installation location

The device must only be installed and used in dry, interior 
spaces. Avoid condensation.

The device is to be installed flush to the wall surface. When selecting an installation
location, please ensure that the measurement results of the integrated tempera-
ture/humidity sensor are affected as little as possible by external influences. Pos-
sible sources of interference include:

Direct sunlight

Drafts from windows and doors

Draft from ducts which lead from other rooms to the concealed box

Warming or cooling of the building structure on which the device is 
mounted, e.g. due to sunlight, heating or cold water pipes

Connection lines which lead from warmer or colder areas to the device

Cut-out dimensions for concealed box:

 

W = 166 mm +1 -0 | H = 116 mm +1 -0 | D = 80 mm

An external antenna can be connected in order to improve wireless communica-
tions. During installation, a 

conduit 50 cm in length

 should be placed beneath

the recessed housing, in which the external antenna can be mounted (antenna di-
mensions approx. 565 x 8 x 5, L × W × H in mm):

Preparing for installation

Wall-fitting

Cavity wall fitting

Assembling the control unit with concealed box

During electrical installation, please introduce all connection cables into the con-
cealed box through the lower or upper side wall. In the process, keep the individual
connection wires short to prevent long reserve loops.

After connecting the cables screw the security covering onto the concealed box. 

The security covering must be fixed before the control is put 
into operation! It prevents contact with current-carrying parts 
in the concealed box.

By adjusting the mounting screws, the display unit will rest flat on the wall later
and be held by the magnets safely.

Connect the flat ribbon cable to the display and place the display unit on the con-
cealed box. The magnets must be attracted by the mounting screws considerably
and the display unit must rest tightly on the concealed box.

Connection diagrams

Drive and MF outputs WS1-PF:

Conduit angled diagonally 
downwards (for cable access 
from above or below)

Conduit angled vertically downwards (only 
for cable access from above!)

concealed

concealed

45°

cable

cable

box

box

M16 conduit, 50 cm in length

M16 conduit, 
50 cm in length

The display unit is held by magnets. Re-
move the front part from the concealed
box.

Caution: The display is connected
with a flat-ribbon cable to the circuit
board in the concealed box.

Loosen the plug so that the display unit
can be removed.

Remove all parts of the transportation
lock/packing.

The security covering in the concealed
box is attached with four screws: Loosen
the screws and take off the security cover-
ing.

Remove the circuit board from the conce-
aled box to be installed a keep it in a place
where it is protected from dirt. 

It may ne-

ver be exposed to dust or moisture!

Place the concealed box in the wall so that
the arrows point upwards.

For fitting, screw the cover (board) on to
the concealed box with the enclosed
screws.

Clamp the concealed box to the wall with
the four enclosed screws.

Upon delivery, the pouch containing the
assembly screws can be found in the con-
trol unit’s concealed box.

or

Adjust the screws of the magnetic moun-
ting with the enclosed template. Each of
the four screws must be adjusted individi-
ally in height. 

When the edge of the template rests on
the wall surface (1), the template must
rest on the mounting screws as well (2).

1

1

2

1 Mains connection 

L/N/PE 230 V/50 Hz

2 Drive group 1
3 Drive group 2
4 Drive group 3
5 Drive group 4
6 Multifunctional output 1 

(potential-free)

7 MF output 2 (potential-free)
8 Microfuse T630 mA
9 Wall button 1 

(terminal 1: +12 V | 2: Up | 3: Down)

10 Wall button 2 

(4: +12 V | 5: Up | 6: Down)

11 Wall button 3 

(7: +12 V | 8: Up | 9: Down)

12 Wall button 4 

(10:+12V|11:Up|12:Down)

13 Weather station (terminals 1-2)
14*Multifunctional input 1 

(terminal 3: +12 V | 4: GND | 5: IN)

15*MF input 2 (6: +12 V | 7: GND | 8: IN)
16 Connector for flat-ribbon cable to 

front board

* Supply voltage e. g. indoor sensor 

possible via MF inputs 
(No. 14, terminal 3(+), 4(-) and 
No. 15, terminal 6(+), 7(-)), 
max. 50 mA altogether.